Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Chincarini, Andrea [VerfasserIn]   i
 Büsing, Karen-Anett [VerfasserIn]   i
Titel:Semi-quantification and grading of amyloid PET
Titelzusatz:a project of the European Alzheimer's Disease Consortium (EADC)
Verf.angabe:A. Chincarini, E. Peira, S. Morbelli, M. Pardini, M. Bauckneht, J. Arbizu, M. Castelo-Branco, K.A. Büsing, A. de Mendonça, M. Didic, M. Dottorini, S. Engelborghs, C. Ferrarese, G.B. Frisoni, V. Garibotto, E. Guedj, L. Hausner, J. Hugon, J. Verhaeghe, P. Mecocci, M. Musarra, M. Queneau, M. Riverol, I. Santana, U.P. Guerra, F. Nobili
E-Jahr:2019
Jahr:04 May 2019
Umfang:13 S.
Fussnoten:Gesehen am 29.11.2019
Titel Quelle:Enthalten in: NeuroImage: Clinical
Ort Quelle:[Amsterdam u.a.] : Elsevier, 2012
Jahr Quelle:2019
Band/Heft Quelle:23(2019) Artikel-Nummer 101846, 13 Seiten
ISSN Quelle:2213-1582
Abstract:Background - amyloid-PET reading has been classically implemented as a binary assessment, although the clinical experience has shown that the number of borderline cases is non negligible not only in epidemiological studies of asymptomatic subjects but also in naturalistic groups of symptomatic patients attending memory clinics. In this work we develop a model to compare and integrate visual reading with two independent semi-quantification methods in order to obtain a tracer-independent multi-parametric evaluation. - Methods - We retrospectively enrolled three cohorts of cognitively impaired patients submitted to 18F-florbetaben (53 subjects), 18F-flutemetamol (62 subjects), 18F-florbetapir (60 subjects) PET/CT respectively, in 6 European centres belonging to the EADC. The 175 scans were visually classified as positive/negative following approved criteria and further classified with a 5-step grading as negative, mild negative, borderline, mild positive, positive by 5 independent readers, blind to clinical data. Scan quality was also visually assessed and recorded. Semi-quantification was based on two quantifiers: the standardized uptake value (SUVr) and the ELBA method. We used a sigmoid model to relate the grading with the quantifiers. We measured the readers accord and inconsistencies in the visual assessment as well as the relationship between discrepancies on the grading and semi-quantifications. - Conclusion - It is possible to construct a map between different tracers and different quantification methods without resorting to ad-hoc acquired cases. We used a 5-level visual scale which, together with a mathematical model, delivered cut-offs and transition regions on tracers that are (largely) independent from the population. All fluorinated tracers appeared to have the same contrast and discrimination ability with respect to the negative-to-positive grading. We validated the integration of both visual reading and different quantifiers in a more robust framework thus bridging the gap between a binary and a user-independent continuous scale.
DOI:doi:10.1016/j.nicl.2019.101846
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

kostenfrei: Volltext: https://doi.org/10.1016/j.nicl.2019.101846
 kostenfrei: Volltext: http://www.sciencedirect.com/science/article/pii/S2213158219301962
 DOI: https://doi.org/10.1016/j.nicl.2019.101846
Datenträger:Online-Ressource
Sprache:eng
Sach-SW:Amyloid PET
 Semi-quantification
 Visual assessment
K10plus-PPN:1683851986
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68461859   QR-Code
zum Seitenanfang