Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Scharnagl, Hubert [VerfasserIn]   i
 Stojakovic, Tatjana [VerfasserIn]   i
 Dieplinger, Benjamin [VerfasserIn]   i
 Dieplinger, Hans [VerfasserIn]   i
 Erhart, Gertraud [VerfasserIn]   i
 Kostner, Gerhard M. [VerfasserIn]   i
 Herrmann, Markus [VerfasserIn]   i
 März, Winfried [VerfasserIn]   i
 Grammer, Tanja B. [VerfasserIn]   i
Titel:Comparison of lipoprotein (a) serum concentrations measured by six commercially available immunoassays
Verf.angabe:Hubert Scharnagl, Tatjana Stojakovic, Benjamin Dieplinger, Hans Dieplinger, Gertraud Erhart, Gerhard M. Kostner, Markus Herrmann, Winfried März, Tanja B. Grammer
E-Jahr:2019
Jahr:27 August 2019
Umfang:8 S.
Fussnoten:Gesehen am 16.12.2019
Titel Quelle:Enthalten in: Atherosclerosis
Ort Quelle:Amsterdam [u.a.] : Elsevier Science, 1970
Jahr Quelle:2019
Band/Heft Quelle:289(2019), Seite 206-213
ISSN Quelle:1879-1484
Abstract:Background and aims - Lipoprotein (a) [Lp(a)] is an established causal risk factor for cardiovascular disease (CVD), independently of low-density lipoproteins (LDL) and other risk factors. The recognition of Lp(a) as an atherogenic molecule has raised the demand for reliable quantification methods in the clinical laboratory. The aim of this work is to compare commercial immunochemical assays. - Methods - We measured Lp(a) serum concentrations using six different assays, providing Lp(a) in mg/dl (Denka Seiken, Abbott Quantia, Beckman, Diasys 21FS, and Siemens N Latex) or in nmol/l (Roche TinaQuant, Diasys 21 FS) in 144 serum samples covering the clinically relevant range of Lp(a) concentrations. All assays relied on five-point calibrations using calibrators provided by the manufacturers. Apolipoprotein(a) phenotyping was performed by sodium dodecyl sulfate-agarose gel electrophoresis (SDS-agarose) followed by immunoblotting. - Results - Most bivariate correlation coefficients were greater than 0.90. Compared to an established IFCC-proposed reference material, the results of the different assays diverged from the target values (43.3 mg/dl or 96.6 nmol/l) by −8% (Siemens N Latex) and +22% (Abbott Quantia). Stratification of the samples into five groups with increasing Lp(a) concentrations and difference plots showed that the differences among assays were concentration-dependent. Some assays overestimated Lp(a) at high concentrations compared to the Denka Seiken assay. - Conclusions - Current commercial immunological assays for measuring Lp(a) concentrations are differently calibrated. Their biases differ significantly across the clinically relevant concentration range in a non-linear manner. This is not conclusively explained by apolipoprotein (a) phenotypes. Further international efforts to harmonize assays for Lp(a) are needed.
DOI:doi:10.1016/j.atherosclerosis.2019.08.015
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext: https://doi.org/10.1016/j.atherosclerosis.2019.08.015
 Verlag: http://www.sciencedirect.com/science/article/pii/S0021915019314601
 DOI: https://doi.org/10.1016/j.atherosclerosis.2019.08.015
Datenträger:Online-Ressource
Sprache:eng
Sach-SW:Atherosclerosis
 Harmonization
 Lipoprotein (a) assays
 Myocardial infarction
K10plus-PPN:1685680828
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68468138   QR-Code