Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Trinkmann, Frederik [VerfasserIn]   i
 Michels-Zetsche, Julia D. [VerfasserIn]   i
 Dösch, Christina [VerfasserIn]   i
 Weiß, Christel [VerfasserIn]   i
 Schönberg, Stefan [VerfasserIn]   i
 Akın, Ibrahim [VerfasserIn]   i
 Borggrefe, Martin [VerfasserIn]   i
 Papavassiliu, Theano [VerfasserIn]   i
 Saur, Joachim [VerfasserIn]   i
Titel:Influence of electrode positioning on accuracy and reproducibility of electrical velocimetry cardiac output measurements
Verf.angabe:Frederik Trinkmann, Manuel Berger, Julia D. Michels, Christina Doesch, Christel Weiss, Stefan O. Schoenberg, Ibrahim Akin, Martin Borggrefe, Theano Papavassiliu, Joachim Saur
E-Jahr:2016
Jahr:2 August 2016
Umfang:14 S.
Fussnoten:Gesehen am 18.12.2019
Titel Quelle:Enthalten in: Physiological measurement
Ort Quelle:Bristol : IOP Publ., 1993
Jahr Quelle:2016
Band/Heft Quelle:37(2016), 9, Seite 1422-1435
ISSN Quelle:1361-6579
Abstract:Electrical velocimetry (EV) is one of the most recent adaptions of impedance cardiography. Previous studies yielded diverging results identifying several factors negatively influencing accuracy. Although electrode arrangement is suspected to be an influencing factor for impedance cardiography in general, no data for EV is available. We aimed to prospectively assess the influence of electrode position on the accuracy and reproducibility of cardiac output (CO) measurements obtained by EV. Two pairs of standard electrocardiographic electrodes were placed at predefined positions of the thorax in 81 patients. The inter-electrode gap was varied between either 5 or 15 cm by caudal movement of the lowest electrode. Measurements were averaged over 20 s and performed twice at each electrode position. Reference values were determined using cardiac magnetic resonance imaging (CMR). Mean bias was 1.2 ± 1.6 l min−1 (percentage error 22 ± 28%) between COCMR and COEV at the 5 cm gap significantly improving to 0.5 ± 1.6 l min−1 (8 ± 28%) when increasing the gap (p < 0.0001). The mean difference between repeated measurements was 0.0 ± 0.3 l min−1 for the 5 cm and 0.1 ± 0.3 l min−1 for the 15 cm gap, respectively (p = 0.3). The accuracy of EV can be significantly improved when increasing the lower inter-electrode gap still exceeding the Critchley and Critchley recommendations. Therefore, absolute values should not be used interchangeably in clinical routine. As the reproducibility was not negatively affected, serial hemodynamic measurements can be reliably acquired in stable patients when the electrode position remains unchanged.
DOI:doi:10.1088/0967-3334/37/9/1422
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext: https://doi.org/10.1088/0967-3334/37/9/1422
 Verlag: https://doi.org/10.1088%2F0967-3334%2F37%2F9%2F1422
 DOI: https://doi.org/10.1088/0967-3334/37/9/1422
Datenträger:Online-Ressource
Sprache:eng
K10plus-PPN:1685933815
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68469439   QR-Code
zum Seitenanfang