Titel:Active-scanned protons and carbon ions in cancer treatment of patients with cardiac implantable electronic devices
Titelzusatz:experience of a single institution
Verf.angabe:Katharina Seidensaal, Semi Ben Harrabi, Eberhard Scholz, Malte Ellerbrock, Thomas Haberer, Fabian Weykamp, Matthias Mattke, Stefan E. Welte, Klaus Herfarth, Jürgen Debus and Matthias Uhl
E-Jahr:2019
Jahr:22 August 2019
Fussnoten:Gesehen am 19.12.2019
Titel Quelle:Enthalten in: Frontiers in oncology
Ort Quelle:Lausanne : Frontiers Media, 2011
Jahr Quelle:2019
Band/Heft Quelle:9(2019) Artikel-Nummer 798, 6 Seiten
ISSN Quelle:2234-943X
Abstract:Background: Ionizing radiation was shown to be able to influence the function of cardiac implantable electronic devices (CIED’s) leading to malfunctions with potentially severe consequences. Those effects presumably correlate with beam energy and neutron production. Thus, restraining has been proclaimedparticle facilities are commonly cautious to for the treatment of patientstreat patients with CIED’s with particles, but substantial evidence is lacking. Methods and Materials: In total 31 patients were investigated, who have been treated at the Heidelberg Ion-Beam Therapy Center (HIT) from September 2012 to February 2019 with protons and carbon ions in active-scanning technique. All CIED’s were checked after every single irradiation by the department of cardiology. The minimum distance between the CIED and the planning target volume (PTV), the 10% isodose and the single beam in Beam’s Eye View (BEV) was analyzed for 12 patients. Results: In total, 31 patients received 32 courses of radiotherapy (RT). Twenty-two received treatment with carbon ion beam and ten with proton beam. The cumulative number of fractions was 582, the cumulative number of documented controls after RT was 504 (87%). Three patients had an implantable cardioverter-defibrillator (ICD) and 28 patients had a pacemaker at the time of treatment. Seven patients had a heart rate of ≤30 /min. The majority of patients (69%) were treated for tumors of the head and neck. The median minimum distance between CIED and PTV, 10 % isodose and the single beam on BEV was 13.4 cm, 11.6 cm and 8.3 cm, respectively. There were no registered events associated with the treatment in this evaluation. Conclusion: Treatment of CIED-patients with protons and carbon ions applied with active raster scanning technique was safe without any incidents in our single center experience. Monitoring after almost every fraction provided systematic and extensive data. Further investigations are necessary in order to form reliable guidelines, which should consider different modes of beam application, as active scanning supposedly provides a greater level of safety from malfunctions for patients with CIED undergoing particle irradiation.
DOI:doi:10.3389/fonc.2019.00798
URL:Kostenfrei: Volltext ; Verlag: https://doi.org/10.3389/fonc.2019.00798
 Kostenfrei: Volltext: https://www.frontiersin.org/articles/10.3389/fonc.2019.00798/full
 DOI: https://doi.org/10.3389/fonc.2019.00798
Datenträger:Online-Ressource
Sprache:eng
Sach-SW:Beam scanning
 Cardiac implantable electronic device
 CIED malfunction
 particle therapy
 Proton therapy
K10plus-PPN:1686087578
Verknüpfungen:→ Zeitschrift
 
 
Lokale URL UB: Zum Volltext

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68470010   QR-Code
zum Seitenanfang