Titel: | Clinical safety of ProMRI implantable cardioverter-defibrillator systems during head and lower lumbar magnetic resonance imaging at 1.5 Tesla |
Verf.angabe: | Wolfgang Rudolf Bauer, Dennis H. Lau, Christian Wollmann, Andrew McGavigan, Jacques Mansourati, Theresa Reiter, Simone Frömer, Mark E. Ladd & Harald H. Quick |
E-Jahr: | 2019 |
Jahr: | 03 December 2019 |
Fussnoten: | Gesehen am 22.01.2020 |
Titel Quelle: | Enthalten in: Scientific reports |
Ort Quelle: | [London] : Macmillan Publishers Limited, part of Springer Nature, 2011 |
Jahr Quelle: | 2019 |
Band/Heft Quelle: | 9(2019) Artikel-Nummer 18243, 11 Seiten |
ISSN Quelle: | 2045-2322 |
Abstract: | Magnetic resonance imaging (MRI) has long been contraindicated in patients with implanted pacemakers, defibrillators, and cardiac resynchronisation therapy (CRT) devices due to the risk of adverse effects through electromagnetic interference. Since many recipients of these devices will have a lifetime indication for an MRI scan, the implantable systems should be developed as ‘MRI-conditional’ (be safe for the MRI environment under predefined conditions). We evaluated the clinical safety of several Biotronik ProMRI (‘MRI-conditional’) defibrillator and CRT systems during head and lower lumbar MRI scans at 1.5 Tesla. The study enrolled 194 patients at 22 sites in Australia, Canada, and Europe. At ≥9 weeks after device implantation, predefined, non-diagnostic, specific absorption rate (SAR)-intensive head and lower lumbar MRI scans (total ≈30 minutes per patient) were performed in 146 patients that fulfilled pre-procedure criteria. Three primary endpoints were evaluated: freedom from serious adverse device effects (SADEs) related to MRI and defibrillator/CRT (leading to death, hospitalisation, life-threatening condition, or potentially requiring implanted system revision or replacement), pacing threshold increase, and sensing amplitude decrease, all at the 1-month post-MRI clinical visit. No MRI-related SADE occurred. Lead values remained stable, measured in clinic and monitored daily by the manufacturer home monitoring technology. |
DOI: | doi:10.1038/s41598-019-54342-4 |
URL: | Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.
Volltext ; Verlag: https://doi.org/10.1038/s41598-019-54342-4 |
| Volltext: https://www.nature.com/articles/s41598-019-54342-4 |
| DOI: https://doi.org/10.1038/s41598-019-54342-4 |
Datenträger: | Online-Ressource |
Sprache: | eng |
K10plus-PPN: | 1688056904 |
Verknüpfungen: | → Zeitschrift |
Clinical safety of ProMRI implantable cardioverter-defibrillator systems during head and lower lumbar magnetic resonance imaging at 1.5 Tesla / Bauer, Wolfgang Rudolf [VerfasserIn]; 03 December 2019 (Online-Ressource)