Titel:Accuracy and revision rate of intraoperative computed tomography point-to-point navigation for lateral mass and pedicle screw placement
Titelzusatz:11-year single-center experience in 1054 patients
Verf.angabe:Basem Ishak, Alexander Younsi, Carola Wieckhusen, Paula Slonczewski, Andreas W. Unterberg, Karl L. Kiening
Jahr:2019
Umfang:11 S.
Fussnoten:Gesehen am 06.02.2020 ; First online: 19 December 2018
Titel Quelle:Enthalten in: Neurosurgical review
Ort Quelle:Berlin : Springer, 1978
Jahr Quelle:2019
Band/Heft Quelle:42(2019), 4, Seite 895-905
ISSN Quelle:1437-2320
Abstract:High accuracy in intraoperative computed tomography (iCT) navigation utilizing an intraoperatively acquired dataset for screw placement in the spine has been reported in the literature. To further improve the accuracy and counteract any intraoperative movement of predefined registration points, we introduce an iCT point-to-point navigation, where marker screws are inserted intraoperatively to increase patient safety. In all, 1054 patients who underwent iCT point-to-point navigation for lateral mass and pedicle screw placement were retrospectively analyzed between 09/2005 and 09/2016. Implant-related complications such as screw misplacement, screw loosening, and revision rate were determined. Furthermore, we investigated the rate of complications and the clinical outcome. In total, 6059 screws were inserted in 1054 patients. There were 553 (52.5%) female and 501 (47.5%) male patients. Average age was 63.5 years, mean BMI 27.5 (SD 13.9). Here, 1427 (23.5%) screws were inserted in the cervical, 995 (16.4%) in the thoracic, 3167 (52.3%) in the lumbar, and 470 (7.8%) in the sacral spine. Eight patients required a revision procedure for screw misplacement (0.8%). Total screw misplacement rate was 0.3% (16/6059). With the use of reference markers in iCT-based, spinal, point-to-point navigation, we achieved a high accuracy of screw placement with a low revision rate (0.8%) and a total screw misplacement rate of 0.3%.
DOI:doi:10.1007/s10143-018-01067-z
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext: https://doi.org/10.1007/s10143-018-01067-z
 Volltext: http://link.springer.com/10.1007/s10143-018-01067-z
 DOI: https://doi.org/10.1007/s10143-018-01067-z
Datenträger:Online-Ressource
Sprache:eng
Sach-SW:Computer-assisted spinal surgery
 Intraoperative CT
 Point-to-point navigation
 Spinal instrumentation
K10plus-PPN:1689519126
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68485498   QR-Code
zum Seitenanfang