Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Augustin, Heiko [VerfasserIn]   i
 Berger, Niklaus [VerfasserIn]   i
 Blattgerste, Christoph [VerfasserIn]   i
 Dittmeier, Sebastian [VerfasserIn]   i
 Ehrler, F. [VerfasserIn]   i
 Grzesik, C. [VerfasserIn]   i
 Hammerich, Jan [VerfasserIn]   i
 Herkert, Adrian [VerfasserIn]   i
 Huth, Lennart [VerfasserIn]   i
 Immig, David [VerfasserIn]   i
 Kozlinskiy, A. [VerfasserIn]   i
 Köppel, M. [VerfasserIn]   i
 Kröger, Jens [VerfasserIn]   i
 Meier Aeschbacher, Frank [VerfasserIn]   i
 Meneses González, Annie [VerfasserIn]   i
 Müller, M. [VerfasserIn]   i
 Noethe, Lars [VerfasserIn]   i
 Perić, I. [VerfasserIn]   i
 Prathapan, M. [VerfasserIn]   i
 Rudzki, Thomas [VerfasserIn]   i
 Schimassek, R. [VerfasserIn]   i
 Schöning, André [VerfasserIn]   i
 Sorokin, I. [VerfasserIn]   i
 Stieler, F. [VerfasserIn]   i
 Tyukin, A. [VerfasserIn]   i
 Wagner, T. [VerfasserIn]   i
 Wauters, F. [VerfasserIn]   i
 Weber, Alena [VerfasserIn]   i
 Wiedner, Dirk [VerfasserIn]   i
 Zhang, H. [VerfasserIn]   i
 Zimmermann, M. [VerfasserIn]   i
Titel:Performance of the large scale HV-CMOS pixel sensor MuPix8
Verf.angabe:H. Augustin, N. Berger, C. Blattgerste, S. Dittmeier, F. Ehrler, C. Grzesik, J. Hammerich, A. Herkert, L. Huth, D. Immig, A. Kozlinskiy, M. Köppel, J. Kröger, F. Meier, A. Meneses Gonzales, M. Müller, L. Noehte, I. Perić, M. Prathapan, T. Rudzki, R. Schimassek, A. Schöning, I. Sorokin, F. Stieler, A. Tyukin, T. Wagner, F. Wauters, A. Weber, D. Wiedner, H. Zhang, M. Zimmermann
E-Jahr:2019
Jahr:8 October 2019
Fussnoten:Gesehen am 25.02.2020
Titel Quelle:Enthalten in: Journal of Instrumentation
Ort Quelle:London : Inst. of Physics, 2006
Jahr Quelle:2019
Band/Heft Quelle:14(2019,10) Artikel-Nummer C10011, ? Seiten
ISSN Quelle:1748-0221
Abstract:The Mu3e experiment is searching for the charged lepton flavour violating decay\break μ+→ e+ e− e+, aiming for an ultimate sensitivity of one in 1016 decays. In an environment of up to 109 muon decays per second the detector needs to provide precise vertex, time and momentum information to suppress accidental and physics background. The detector consists of cylindrical layers of 50 μm thin High Voltage Monolithic Active Pixel Sensors (HV-MAPS) placed in a 1 T magnetic field. The measurement of the trajectories of the decay particles allows for a precise vertex and momentum reconstruction. Additional layers of fast scintillating fibre and tile detectors provide sub-nanosecond time resolution. The MuPix8 chip is the first large scale prototype, proving the scalability of the HV-MAPS technology. It is produced in the AMS aH18 180 nm HV-CMOS process. It consists of three sub-matrices, each providing an untriggered datastream of more than 10 MHits/s. The latest results from laboratory and testbeam characterisation are presented, showing an excellent performance with efficiencies >99.6 % and a time resolution better than 10 ns achieved with time walk correction.
DOI:doi:10.1088/1748-0221/14/10/C10011
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext: https://doi.org/10.1088/1748-0221/14/10/C10011
 Verlag: https://doi.org/10.1088%2F1748-0221%2F14%2F10%2Fc10011
 DOI: https://doi.org/10.1088/1748-0221/14/10/C10011
Datenträger:Online-Ressource
Sprache:eng
K10plus-PPN:169091176X
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68492902   QR-Code
zum Seitenanfang