| Online-Ressource |
Verfasst von: | Şen, Sinan [VerfasserIn]  |
| Orhan, Gül [VerfasserIn]  |
| Zingler, Sebastian [VerfasserIn]  |
| Katsikogianni, Eleni [VerfasserIn]  |
| Lux, Christopher J. [VerfasserIn]  |
| Erber, Ralf [VerfasserIn]  |
Titel: | Comparison of crevicular fluid cytokine levels after the application of surface sealants |
Titelzusatz: | a randomized trial |
Verf.angabe: | Sinan Şen, Gül Orhan, Sebastian Zingler, Eleni Katsikogianni, Christopher J. Lux, Ralf Erber |
E-Jahr: | 2019 |
Jahr: | 22 July 2019 |
Umfang: | 10 S. |
Fussnoten: | Gesehen am 02.03.2020 |
Titel Quelle: | Enthalten in: Journal of orofacial orthopedics |
Ort Quelle: | München : Urban & Vogel, 1931 |
Jahr Quelle: | 2019 |
Band/Heft Quelle: | 80(2019), 5, Seite 242-253 |
ISSN Quelle: | 1615-6714 |
Abstract: | Purpose Surface sealants are widely used in orthodontic practice to avoid enamel decalcifications in patients treated with fixed orthodontic appliances. While their clinical benefit was tested in several studies, their biocompatibility has been evaluated to a lesser extent. Therefore, the aim of this randomized prospective study was to evaluate possible adverse biological effects of three commonly used surface sealants and a bonding primer on gingival tissues by analysing cytokines in crevicular fluid of orthodontic patients after the application of surface sealants. - Methods A single centre parallel trial was conducted. Using a split-mouth design quadrants of 15 patients requiring orthodontic treatment with fixed appliances were randomized to one of three commonly used surface sealants (Pro Seal®, Opal®Seal™, Protecto®CaF2Nano) and a bonding primer (Transbond™ XT). Interleukin (IL)-8 and IL-10 levels in crevicular fluids of the individual quadrants were assessed at four different time points (before application, and at 30, 60 and 90 min after application). - Results In all, 60 quadrants of 15 patients were randomized (Pro Seal® n = 15, Opal®Seal™ n = 15, Protecto®CaF2Nano n = 15, Transbond™ XT n = 15) and analysed. No significant changes for IL-8 or IL-10 levels in crevicular fluid after the application of surface sealants or bonding primer were detected. However, interpatient variability was high. No further clinical side effects were detected. - Conclusions Commonly used pre-bonding surface sealants (Pro Seal®, Opal®Seal™) do not appear to have a significant impact on inflammatory cytokines levels of crevicular fluid and do not appear to contribute to sensitization or hypersensitivity events. |
DOI: | doi:10.1007/s00056-019-00184-8 |
URL: | Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.
Volltext ; Verlag: https://doi.org/10.1007/s00056-019-00184-8 |
| Volltext: http://link.springer.com/10.1007/s00056-019-00184-8 |
| DOI: https://doi.org/10.1007/s00056-019-00184-8 |
Datenträger: | Online-Ressource |
Sprache: | eng |
K10plus-PPN: | 1691436623 |
Verknüpfungen: | → Zeitschrift |
Comparison of crevicular fluid cytokine levels after the application of surface sealants / Şen, Sinan [VerfasserIn]; 22 July 2019 (Online-Ressource)