| Online-Ressource |
Verfasst von: | Wielpütz, Mark Oliver [VerfasserIn]  |
| Kauczor, Hans-Ulrich [VerfasserIn]  |
Titel: | Morphologic characterization of pulmonary nodules with ultrashort TE MRI at 3T |
Verf.angabe: | Mark O. Wielpütz, Ho Yun Lee, Hisanobu Koyama, Takeshi Yoshikawa, Shinichiro Seki, Yuji Kishida, Yasuhiro Sakai, Hans-Ulrich Kauczor, Kazuro Sugimura, Yoshiharu Ohno |
Jahr: | 2018 |
Umfang: | 13 S. |
Fussnoten: | Gesehen am 16.03.2020 |
Titel Quelle: | Enthalten in: American journal of roentgenology |
Ort Quelle: | Leesburg, Va. : American Roentgen Ray Society, 1965 |
Jahr Quelle: | 2018 |
Band/Heft Quelle: | 210(2018), 6, Seite 1216-1225 |
ISSN Quelle: | 1546-3141 |
Abstract: | Objective: Ultrashort TE (UTE) MRI has been shown to deliver high-resolution images comparable to CT images. Here we evaluate the potential of UTE-MRI for precise lung nodule characterization. Subjects and methods: Fifty-one patients (mean [± SD] age, 68.7 ± 10.8 years) with 119 nodules or masses (mean size, 17.4 ± 16.3 mm; range, 4–88 mm) prospectively underwent CT (1-mm slice thickness) and UTE-MRI (TE, 192 μs; 1 mm3 resolution). Two radiologists assessed nodule dimensions and morphologic features (i.e., attenuation, margins, and internal lucencies), in consensus for CT and in a blinded fashion for UTE-MRI. Sensitivity, specificity, and kappa statistics were calculated in reference to CT. Results: Readers 1 and 2 underestimated the nodules' long axial diameter with UTEMRI by 1.2 ± 3.4 and 2.1 ± 4.2 mm, respectively (p < 0.001). The sensitivity and specificity of UTE-MRI for subsolid attenuation were 95.9% and 70.3%, respectively, for reader 1 and 97.1% and 71.4%, respectively, for reader 2 (κ = 0.71 and 0.68). With regard to margin characteristics, for lobulation, sensitivity was 70.6% and 54.9%, and specificity was 93.2% and 96.3% for readers 1 and 2, respectively; for spiculation, sensitivity was 61.5% and 48.0%, and specificity was 95.2% and 95.0%; and for pleural tags, sensitivity was 87.0% and 73.3%, and specificity was 93.8% and 95.0%. Finally, for internal lucencies, sensitivity was 72.7% and 61.3%, and specificity was 96.1% and 97.3% for readers 1 and 2, respectively (κ = 0.64–0.81 for reader 1 and 0.48–0.72 for reader 2). Interreader agreement for attenuation, margin characteristics, and lucencies was substantial to almost perfect with few exceptions (κ = 0.51–0.90). Conclusion: UTE-MRI systematically underestimated dimension measurements by approximately 1–2 mm but otherwise showed high diagnostic properties and interreader agreement, yet unprecedented by MRI, for nodule morphologic assessment. |
DOI: | doi:10.2214/AJR.17.18961 |
URL: | Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.
Volltext ; Verlag: https://doi.org/10.2214/AJR.17.18961 |
| Volltext: https://www.ajronline.org/doi/10.2214/AJR.17.18961 |
| DOI: https://doi.org/10.2214/AJR.17.18961 |
Datenträger: | Online-Ressource |
Sprache: | eng |
Sach-SW: | dimensional measurement accuracy |
| lung neoplasms |
| MDCT |
| MRI |
| solitary pulmonary nodule |
K10plus-PPN: | 1692615300 |
Verknüpfungen: | → Zeitschrift |
Morphologic characterization of pulmonary nodules with ultrashort TE MRI at 3T / Wielpütz, Mark Oliver [VerfasserIn]; 2018 (Online-Ressource)