| Online-Ressource |
Verfasst von: | Aad, Georges [VerfasserIn]  |
| Anders, Christoph [VerfasserIn]  |
| Andrei, George Victor [VerfasserIn]  |
| Antel, Claire [VerfasserIn]  |
| Bolz, Arthur [VerfasserIn]  |
| Brandt, Oleg [VerfasserIn]  |
| Dunford, Monica [VerfasserIn]  |
| Ferreira de Lima, Danilo Enoque [VerfasserIn]  |
| Franchino, Silvia [VerfasserIn]  |
| Geisler, Manuel Patrice [VerfasserIn]  |
| Helary, Louis [VerfasserIn]  |
| Jongmanns, Jan [VerfasserIn]  |
| Klassen, Martin [VerfasserIn]  |
| Kolb, Mathis [VerfasserIn]  |
| Krishnan, Anjali [VerfasserIn]  |
| Kugel, Andreas [VerfasserIn]  |
| Lisovyi, Mykhailo [VerfasserIn]  |
| Meyer zu Theenhausen, Hanno [VerfasserIn]  |
| Napolitano, Fabrizio [VerfasserIn]  |
| Ott, Philipp [VerfasserIn]  |
| S̜ahinsoy, Merve [VerfasserIn]  |
| Schöning, André [VerfasserIn]  |
| Schultz-Coulon, Hans-Christian [VerfasserIn]  |
| Spieker, Thomas [VerfasserIn]  |
| Stamen, Rainer [VerfasserIn]  |
| Starovoitov, Pavel [VerfasserIn]  |
| Suchek, Stanislav [VerfasserIn]  |
| Vigani, Luigi [VerfasserIn]  |
| Wang, Jike [VerfasserIn]  |
| Weber, Sebastian [VerfasserIn]  |
| Wessels, Martin [VerfasserIn]  |
| Yue, Xiaoguang [VerfasserIn]  |
Titel: | Resolution of the ATLAS muon spectrometer monitored drift tubes in LHC Run 2 |
Körperschaft: | ATLAS Collaboration [VerfasserIn]  |
Verf.angabe: | The ATLAS collaboration |
E-Jahr: | 2019 |
Jahr: | September 16, 2019 |
Umfang: | 36 S. |
Fussnoten: | Gesehen am 18.03.2020 ; The ATLAS Collaboration: G. Aad, C.F. Anders, V. Andrei, C. Antel, A.E. Bolz, O. Brandt, M. Dunford, D.E. Ferreira de Lima, S. Franchino, M.P. Geisler, L. Helary, J. Jongmanns, M. Klassen, M. Kolb, A. Krishnan, A. Kugel, M. Lisovyi, H. Meyer zu Theenhausen, F. Napolitano, P. Ott, M. Sahinsoy, A. Schoening, H.-C. Schultz-Coulon, T.M. Spieker, R. Stamen, P. Starovoitov, S. Suchek, J. Wang, S.M. Weber, M. Wessels, X. Yue [und 2904 weitere Personen] |
Titel Quelle: | Enthalten in: Journal of Instrumentation |
Ort Quelle: | London : Inst. of Physics, 2006 |
Jahr Quelle: | 2019 |
Band/Heft Quelle: | 14(2019,09) Artikel-Nummer P09011, 36 Seiten |
ISSN Quelle: | 1748-0221 |
Abstract: | The momentum measurement capability of the ATLAS muon spectrometer relies fundamentally on the intrinsic single-hit spatial resolution of the monitored drift tube precision tracking chambers. Optimal resolution is achieved with a dedicated calibration program that addresses the specific operating conditions of the 354 000 high-pressure drift tubes in the spectrometer. The calibrations consist of a set of timing offsets and drift time to drift distance transfer relations, and result in chamber resolution functions. This paper describes novel algorithms to obtain precision calibrations from data collected by ATLAS in LHC Run 2 and from a gas monitoring chamber, deployed in a dedicated gas facility. The algorithm output consists of a pair of correction constants per chamber which are applied to baseline calibrations, and determined to be valid for the entire ATLAS Run 2. The final single-hit spatial resolution, averaged over 1172 monitored drift tube chambers, is 81.7 ± 2.2 μm. |
DOI: | doi:10.1088/1748-0221/14/09/P09011 |
URL: | Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.
Volltext: https://doi.org/10.1088/1748-0221/14/09/P09011 |
| DOI: https://doi.org/10.1088/1748-0221/14/09/P09011 |
Datenträger: | Online-Ressource |
Sprache: | eng |
K10plus-PPN: | 1692884808 |
Verknüpfungen: | → Zeitschrift |
Resolution of the ATLAS muon spectrometer monitored drift tubes in LHC Run 2 / Aad, Georges [VerfasserIn]; September 16, 2019 (Online-Ressource)