Titel: | Debonding forces for two-piece zirconia abutments with implant platforms of different diameter and use of different luting strategies |
Verf.angabe: | Zenthöfer, Andreas / Rues, Stefan / Krisam, Johannes / Rustemeyer, Rainer / Rammelsberg, Peter / Schmitter, Marc |
E-Jahr: | 2018 |
Jahr: | 04.10.2018 |
Umfang: | 6 S. |
Fussnoten: | Gesehen am 31.03.2020 |
Titel Quelle: | Enthalten in: The international journal of oral & maxillofacial implants |
Ort Quelle: | Batavia : Quintessence Publishing, 1986 |
Jahr Quelle: | 2018 |
Band/Heft Quelle: | 33(2018), 5, Seite 1041-1046 |
ISSN Quelle: | 1942-4434 |
Abstract: | Andreas Zenthöfer, DMD, PhD/Stefan Rues, Dipl.-Ing./Johannes Krisam, PhD/Rainer Rustemeyer/Peter Rammelsberg, DMD, PhD/Marc Schmitter, DMD, PhD: Purpose: The forces needed to detach zirconia copings from titanium inserts of two-piece abutments were - evaluated for implant platforms of different diameters (4.8 and 6.5 mm) and different luting strategies. - Materials and Methods: Eight specimens (four for each platform diameter) were prepared to simulate - two-piece zirconia implant abutments with prefabricated titanium inserts and computer-aided design/computer-aided manufactured (CAD/CAM) zirconia copings. Half of the copings were luted to their titanium - inserts by use of composite cement; the others were luted after additional bonding treatment of the titanium - and zirconia surfaces. All specimens were subjected to tensile forces up to failure. Samples were used with - or without artificial aging. Each specimen was luted and subsequently debonded 12 times; thus, a total of - 96 tests were conducted. Results: All debonding forces exceeded approximately 600 N. Larger platform - diameters (P < .001) and additional bonding treatment (P = .021) resulted in significantly better retention; - artificial aging had no effect (P = .165). Conclusion: Forces for debonding of titanium bases from zirconia - abutments were favorable. The use of these abutments might be a viable prosthetic treatment option in - specific clinical cases. |
DOI: | doi:10.11607/jomi.6300 |
URL: | Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.
Volltext: https://doi.org/10.11607/jomi.6300 |
| Verlag: https://jomi.quintessenz.de/index.php?doc=abstract&abstractID=41250 |
| Volltext: http://quintpub.com/journals/omi/abstract.php?iss2_id=1557&article_id=18745#.XoLfZ3JCQ2x |
| DOI: https://doi.org/10.11607/jomi.6300 |
Datenträger: | Online-Ressource |
Sprache: | eng |
K10plus-PPN: | 1693576252 |
Verknüpfungen: | → Zeitschrift |
Debonding forces for two-piece zirconia abutments with implant platforms of different diameter and use of different luting strategies / Zenthöfer, Andreas [VerfasserIn]; 04.10.2018 (Online-Ressource)