Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Zenthöfer, Andreas [VerfasserIn]   i
 Rues, Stefan [VerfasserIn]   i
 Krisam, Johannes [VerfasserIn]   i
 Rammelsberg, Peter [VerfasserIn]   i
 Schmitter, Marc [VerfasserIn]   i
Titel:Debonding forces for two-piece zirconia abutments with implant platforms of different diameter and use of different luting strategies
Verf.angabe:Zenthöfer, Andreas / Rues, Stefan / Krisam, Johannes / Rustemeyer, Rainer / Rammelsberg, Peter / Schmitter, Marc
E-Jahr:2018
Jahr:04.10.2018
Umfang:6 S.
Fussnoten:Gesehen am 31.03.2020
Titel Quelle:Enthalten in: The international journal of oral & maxillofacial implants
Ort Quelle:Batavia : Quintessence Publishing, 1986
Jahr Quelle:2018
Band/Heft Quelle:33(2018), 5, Seite 1041-1046
ISSN Quelle:1942-4434
Abstract:Andreas Zenthöfer, DMD, PhD/Stefan Rues, Dipl.-Ing./Johannes Krisam, PhD/Rainer Rustemeyer/Peter Rammelsberg, DMD, PhD/Marc Schmitter, DMD, PhD: Purpose: The forces needed to detach zirconia copings from titanium inserts of two-piece abutments were - evaluated for implant platforms of different diameters (4.8 and 6.5 mm) and different luting strategies. - Materials and Methods: Eight specimens (four for each platform diameter) were prepared to simulate - two-piece zirconia implant abutments with prefabricated titanium inserts and computer-aided design/computer-aided manufactured (CAD/CAM) zirconia copings. Half of the copings were luted to their titanium - inserts by use of composite cement; the others were luted after additional bonding treatment of the titanium - and zirconia surfaces. All specimens were subjected to tensile forces up to failure. Samples were used with - or without artificial aging. Each specimen was luted and subsequently debonded 12 times; thus, a total of - 96 tests were conducted. Results: All debonding forces exceeded approximately 600 N. Larger platform - diameters (P < .001) and additional bonding treatment (P = .021) resulted in significantly better retention; - artificial aging had no effect (P = .165). Conclusion: Forces for debonding of titanium bases from zirconia - abutments were favorable. The use of these abutments might be a viable prosthetic treatment option in - specific clinical cases.
DOI:doi:10.11607/jomi.6300
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext: https://doi.org/10.11607/jomi.6300
 Verlag: https://jomi.quintessenz.de/index.php?doc=abstract&abstractID=41250
 Volltext: http://quintpub.com/journals/omi/abstract.php?iss2_id=1557&article_id=18745#.XoLfZ3JCQ2x
 DOI: https://doi.org/10.11607/jomi.6300
Datenträger:Online-Ressource
Sprache:eng
K10plus-PPN:1693576252
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68559599   QR-Code
zum Seitenanfang