Navigation überspringen
Universitätsbibliothek Heidelberg
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Reiner, Tobias [VerfasserIn]   i
 Klotz, Matthias C. M. [VerfasserIn]   i
 Seelmann, Kirsten [VerfasserIn]   i
 Hertzsch, Fabian [VerfasserIn]   i
 Innmann, Moritz Maximilian [VerfasserIn]   i
 Streit, Marcus R. [VerfasserIn]   i
 Nees, Timo A. [VerfasserIn]   i
 Moradi, Babak [VerfasserIn]   i
 Merle, Christian [VerfasserIn]   i
 Kretzer, Jan Philippe [VerfasserIn]   i
 Gotterbarm, Tobias [VerfasserIn]   i
Titel:Long-term results of a second-generation, small-diameter, metal-on-metal bearing in primary total hip arthroplasty at 14-year follow-up
Verf.angabe:Tobias Reiner, Matthias C. Klotz, Kirsten Seelmann, Fabian Hertzsch, Moritz M. Innmann, Marcus R. Streit, Timo A. Nees, Babak Moradi, Christian Merle, Jan Philippe Kretzer and Tobias Gotterbarm
E-Jahr:2020
Jahr:24 January 2020
Umfang:11 S.
Fussnoten:Gesehen am 16.04.2020
Titel Quelle:Enthalten in: Materials
Ort Quelle:Basel : MDPI, 2008
Jahr Quelle:2020
Band/Heft Quelle:13(2020,3) Artikel-Nummer 557, 11 Seiten
ISSN Quelle:1996-1944
Abstract:(1) Background: The objective of the present study was to review the clinical and radiological results of a small-head, MoM bearing in primary THA and to determine blood metal ion levels at long-term follow-up. (2) Methods: We retrospectively evaluated the clinical and radiological results of 284 small-diameter, MoM 28-mm Metasul THA at a mean follow-up of 14.5 years, and measured blood metal ion concentrations in 174 of these patients. (3) Results: After 14 years, survival free for revision due to any reason was 94%. Proximal femoral osteolysis was seen in 23% of hips, and MRI demonstrated ARMD in 27 of the 66 investigated hips (41%). Mean cobalt, chromium, and titanium ion concentrations were 0.82 µg/L (range 0.22-4.45), 1.51 µg/L (0.04-22.69), and 2.68 µg/L (0.26-19.56) in patients with unilateral THA, and 2.59 µg/L (0.43-24.75), 2.50 µg/L (0.26-16.75), and 3.76 µg/L (0.67-19.77), respectively in patients with bilateral THA. Twenty-nine percent of patients showed cobalt or chromium ion levels > 2 µg/L. (4) Conclusions: Despite good clinical long-term results, increased blood metal ion levels (cobalt or chromium > 2 µg/L) were found in approximately one-third of asymptomatic patients, and proximal femoral osteolysis and ARMD were frequently seen in this cohort. Blood metal ion analysis appears helpful in the long-term follow-up of these patients in order to identify individuals at risk. In accordance with contemporary consensus statements, symptomatic patients with elevated metal ion levels and/or progressive osteolysis should be considered for additional CT or MARS MRI to determine the extent of soft tissue affection prior to revision surgery. Further studies are necessary to investigate the clinical relevance of ARMD in asymptomatic patients with small-head, MoM THA.
DOI:doi:10.3390/ma13030557
URL:kostenfrei: Volltext ; Verlag: https://doi.org/10.3390/ma13030557
 kostenfrei: Volltext: https://www.mdpi.com/1996-1944/13/3/557
 DOI: https://doi.org/10.3390/ma13030557
Datenträger:Online-Ressource
Sprache:eng
Sach-SW:28 mm small head
 blood metal ions
 chromium
 cobalt
 metal-on-metal THA
 Metasul
 titanium
K10plus-PPN:1694803015
Verknüpfungen:→ Zeitschrift
 
 
Lokale URL UB: Zum Volltext

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68565427   QR-Code
zum Seitenanfang