Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Weindler, Jan N. [VerfasserIn]   i
 Łabuz, Grzegorz [VerfasserIn]   i
 Yildirim, Timur Mert [VerfasserIn]   i
 Tandogan, Tamer [VerfasserIn]   i
 Khoramnia, Ramin [VerfasserIn]   i
 Auffarth, Gerd U. [VerfasserIn]   i
Titel:The impact of glistenings on the optical quality of a hydrophobic acrylic intraocular lens
Verf.angabe:Jan N. Weindler, MD, Grzegorz Łabuz, PhD, Timur M. Yildirim, MD, Tamer Tandogan, MD, Ramin Khoramnia, MD, FEBO, Gerd U. Auffarth, MD, PhD
Jahr:2019
Umfang:6 S.
Fussnoten:Gesehen am 20.04.2020
Titel Quelle:Enthalten in: Journal of cataract and refractive surgery
Ort Quelle:Fairfax, Va. : Soc., 1986
Jahr Quelle:2019
Band/Heft Quelle:45(2019), 7, Seite 1020-1025
ISSN Quelle:1873-4502
Abstract:Purpose - To study the effect of glistenings on the optical quality of a hydrophobic acrylic intraocular lens (IOL). - Setting - David J. Apple Laboratory, Heidelberg, Germany. - Design - An in vitro laboratory study. - Methods - An accelerated aging protocol was used to induce glistenings (microvacuoles) in 38 hydrophobic acrylic IOLs. The IOLs were warmed to 45°C and then cooled to 37°C. Image analysis of light-microcopy photographs determined the number and size of microvacuoles (MV). A classification was applied based on the glistening number per mm2: grade 0 (none), grade 1 (1-100), grade 2 (101-200), grade 3 (201-500) and grade 4 (more than 500). An optical bench was used to measure each IOL’s modulation transfer function (MTF) and Strehl ratio to evaluate the impact of glistenings on image quality. - Results - Glistenings were observed in all IOLs. The mean glistening numbers ± SD (MV/mm2) in grades 1 through 4 were 74 ± 12.7, 142 ± 22.2, 297 ± 76.2, and 1509 ± 311.9, respectively. The mean glistening sizes in grades 1 through 4 were 13.28 ± 3.85 μm, 15.88 ± 2.08 μm, 16.85 ± 3.23 μm, and 15.27 ± 2.25 μm, respectively. Statistical analysis showed that grades 1 through 3 did not change the optical quality; however, in grade 4, the MTF and the Strehl ratio were significantly affected. - Conclusion - A limited number of glistenings (<500 MV/mm2) had no effect on the image quality. Although statistically significant deteriorations in the MTF and the Strehl ratio were observed in grade 4, the effects found were small and are unlikely to affect the visual quality.
DOI:doi:10.1016/j.jcrs.2019.01.025
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext: https://doi.org/10.1016/j.jcrs.2019.01.025
 Volltext: https://journals.lww.com/jcrs/FullText/2019/07000/The_impact_of_glistenings_on_the_optical_quality.21.aspx
 DOI: https://doi.org/10.1016/j.jcrs.2019.01.025
Datenträger:Online-Ressource
Sprache:eng
K10plus-PPN:1695023226
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68568252   QR-Code
zum Seitenanfang