Titel:IVIM-diffusion-MRI for the differentiation of solid benign and malign hypervascular liver lesions
Titelzusatz:evaluation with two different MR scanners
Verf.angabe:Miriam Klauß, Philipp Mayer, Klaus Maier-Hein, Frederik B. Laun, Arineb Mehrabi, Hans-Ulrich Kauczor, Bram Stieltjes
E-Jahr:2016
Jahr:[2016]
Umfang:6 S.
Illustrationen:Diagramme
Fussnoten:Gesehen am 13.05.2020
Titel Quelle:Enthalten in: European journal of radiology
Ort Quelle:Amsterdam [u.a.] : Elsevier Science, 1990
Jahr Quelle:2016
Band/Heft Quelle:85(2016), 7, Seite 1289-1294
ISSN Quelle:1872-7727
Abstract:Purpose - Hepatocellular carcinoma (HCC) and focal nodular hyperplasia (FNH) as the most common malign and benign liver tumors are both hypervascularized and potentially difficult to differentiate. DWI in liver MRI has been shown to be helpful in the classification of liver lesions, although with a substantial ADC-values-overlap. First results suggest that IVIM allows for improved characterization of liver lesions. In this study we evaluated IVIM-derived parameters in HCC and FNH with two different MR-scanners. - Material and methods - 72 patients (29 FNH, 43HCC) were examined prospectively using two 1.5 T-MRI scanners (Aera/MagnetomAvanto, Siemens, Germany). Quantitative analysis of IVIM-derived parameters and ADC800-values was performed independently by two radiologists. The concordance between the reviewers was tested using a Pearson-/Spearman-correlation. The mean values for significant differences between FNHs and HCCs and between the two MR scanners were compared using a two-tailed t-test/Mann-Whitney-U test. An ROC analysis assessing the diagnostic performance of the parameters was performed. - Results - The concordance between the two f-, D- and D*-measurements were r=0.81, 0.81 and 0.84, and r=0.58 for ADC-values. D-values and ADC800-values were significantly lower in HCC compared to FNH (p<0.001), there was no significant difference for f and D*. D had the largest AUC (0.76) for the differentiation between the two entities. Most parameters were not significantly different between the two MRIs. - Conclusion - IVIM-derived D and ADC are comparable for the differentiation between HCC and FNH. Since ADC-measurement means less effort than IVIM, ADC should be used for the differentiation between the two entities. Furthermore, quantitative results obtained from different scanners match closely.
DOI:doi:10.1016/j.ejrad.2016.04.011
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext ; Verlag: https://doi.org/10.1016/j.ejrad.2016.04.011
 Volltext: http://www.sciencedirect.com/science/article/pii/S0720048X1630122X
 DOI: https://doi.org/10.1016/j.ejrad.2016.04.011
Datenträger:Online-Ressource
Sprache:eng
Sach-SW:DWI
 FNH
 HCC
 IVIM
 Reproducibility
K10plus-PPN:1698121695
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68576302   QR-Code
zum Seitenanfang