Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Koster, T. David [VerfasserIn]   i
 Rikxoort, Eva M. van [VerfasserIn]   i
 Huebner, Ralf-Harto [VerfasserIn]   i
 Doellinger, Felix [VerfasserIn]   i
 Klooster, Karin [VerfasserIn]   i
 Charbonnier, Jean-Paul [VerfasserIn]   i
 Radhakrishnan, Sri [VerfasserIn]   i
 Herth, Felix [VerfasserIn]   i
 Slebos, Dirk-Jan [VerfasserIn]   i
Titel:Predicting lung volume reduction after endobronchial valve therapy is maximized using a combination of diagnostic tools
Verf.angabe:T. David Koster, Eva M. van Rikxoort, Ralf-Harto Huebner, Felix Doellinger, Karin Klooster, Jean-Paul Charbonnier, Sri Radhakrishnan, Felix J. F. Herth, Dirk-Jan Slebos
E-Jahr:2016
Jahr:August 31, 2016
Umfang:8 S.
Fussnoten:Gesehen am 22.05.2020
Titel Quelle:Enthalten in: Respiration
Ort Quelle:Basel : Karger, 1944
Jahr Quelle:2016
Band/Heft Quelle:92(2016), 3, Seite 150-157
ISSN Quelle:1423-0356
Abstract:<b><i>Background:</i></b> Bronchoscopic lung volume reduction using one-way endobronchial valves (EBVs) has been proven to be effective in patients with severe emphysema. However, the selection of patients without collateral ventilation prior to treatment is critical for procedural success. Collateral ventilation can be assessed directly with the Chartis system or indirectly using computed tomography (CT) fissure analysis. <b><i>Objectives:</i></b> We retrospectively evaluated the diagnostic value of a combination of the quantitative CT interlobar fissure completeness score (FCS) and Chartis in predicting responders to EBV therapy. <b><i>Methods:</i></b> CT data from four prospective studies were pooled and analyzed using semiautomated software to quantify the completeness of interlobar fissures. These FCSs were compared to a reference standard of achieving ≥350 ml of target lobe volume reduction after EBV treatment. Using a receiver operating characteristic curve, optimal thresholds predictive of complete fissures (responders) and incomplete fissures (non-responders) were determined. A subgroup of patients with partially complete fissures was identified, where software had lower accuracy. The complementary value of Chartis was investigated in this group. <b><i>Results:</i></b> A fissure was defined as complete (FCS >95%), incomplete (FCS <80%), or partially complete (80% < FCS < 95%). The positive predictive value (PPV) of complete fissures is 88.1%, and the negative predictive value (NPV) is 92.9%, with an overall accuracy of 89.2%. Chartis was utilized in patients with partially complete fissures, with a PPV of 82.3%, an NPV of 84.6%, and an accuracy of 83.3%. <b><i>Conclusion:</i></b> Combining diagnostic tools could reduce the burden on patients and the healthcare system while providing clinicians with a better means for patient selection for EBV therapy.
DOI:doi:10.1159/000448849
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext ; Verlag: https://doi.org/10.1159/000448849
 Volltext: https://www.karger.com/Article/FullText/448849
 DOI: https://doi.org/10.1159/000448849
Datenträger:Online-Ressource
Sprache:eng
K10plus-PPN:1698683111
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68579922   QR-Code
zum Seitenanfang