Titel:Retrieval analysis of modern knee tumor megaendoprosthesis shows considerable volumetric metal wear generated at the rotating hinge
Verf.angabe:Therese Bormann, Sebastian Jäger, J. Philippe Kretzer, Laura Nebel, Lucas Clarius, Georg Omlor, Rudi Bitsch, Burkhard Lehner
E-Jahr:2020
Jahr:26 March 2020
Fussnoten:Gesehen am 27.05.2020
Titel Quelle:Enthalten in: Materials
Ort Quelle:Basel : MDPI, 2008
Jahr Quelle:2020
Band/Heft Quelle:13(2020,7) Artikel-Nummer 1519, 11 Seiten
ISSN Quelle:1996-1944
Abstract:Frequently occurring damage, as well as elevated blood metal ion levels, are reported in relation to a tumor and revision system for total knee arthroplasty (TKA), which applies a rotating hinge coupling with a metal-on-metal (MoM) articulation. As the patient collective for this specific system is small, there is no data on wear generated from the couplings. In this study, wear volume and influencing parameters were investigated at 44 retrieved TKAs with MoM couplings. A scoring system rating frequently occurring abrasive wear between 0 (no wear) and 3 (distinct wear) was established. The wear score was correlated to time in vivo, bone resection length, patient weight and polyethylene inlay damage. Volumetric wear was estimated applying coordinate measurements. An elevated wear score of two or higher was found in 43% of cases. The mean wear rate accounted to 7.8 mm3/year. The main influencing coefficient for the extent of wear is time in vivo. We found a tendency for higher wear scores with higher inlay degradation scores. Patient weight and bone resection length did not impact coupling wear. Assessment of wear damage by a semi-quantitative scoring system has proven to be a reliable option for non-destructive coupling evaluation. The generated wear volume is high.
DOI:doi:10.3390/ma13071519
URL:kostenfrei: Volltext ; Verlag: https://doi.org/10.3390/ma13071519
 kostenfrei: Volltext: https://www.mdpi.com/1996-1944/13/7/1519
 DOI: https://doi.org/10.3390/ma13071519
Datenträger:Online-Ressource
Sprache:eng
Sach-SW:bone tumor
 megaendoprosthesis
 metal wear
 metal-on-metal articulation
 retrieval study
 total knee arthroplasty
 volumetric wear
K10plus-PPN:1698886926
Verknüpfungen:→ Zeitschrift
 
 
Lokale URL UB: Zum Volltext

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68581248   QR-Code
zum Seitenanfang