Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Xu, Jing [VerfasserIn]   i
 Sonntag, Robert [VerfasserIn]   i
 Kretzer, Jan Philippe [VerfasserIn]   i
 Taylor, Dominic [VerfasserIn]   i
 Forst, Raimund [VerfasserIn]   i
 Seehaus, Frank [VerfasserIn]   i
Titel:Model-Based Roentgen Stereophotogrammetric Analysis to Monitor the Head-Taper Junction in Total Hip Arthroplasty in Vivo—And They Do Move
Verf.angabe:Jing Xu, Robert Sonntag, J. Philippe Kretzer, Dominic Taylor, Raimund Forst, Frank Seehaus
E-Jahr:2020
Jahr:27 March 2020
Umfang:21 S.
Fussnoten:Gesehen am 28.05.2020
Titel Quelle:Enthalten in: Materials
Ort Quelle:Basel : MDPI, 2008
Jahr Quelle:2020
Band/Heft Quelle:13(2020,7) Artikel-Nummer 1543, 21 Seiten
ISSN Quelle:1996-1944
Abstract:Model-based Roentgen stereophotogrammetric analysis (RSA) using elementary geometrical shape (EGS) models allows migration measurement of implants without the necessity of additional attached implant markers. The aims of this study were: (i) to assess the possibility of measuring potential head&ndash;taper movement in THA in vivo using model-based RSA and (ii) to prove the validity of measured head&ndash;taper migration data in vitro and in vivo. From a previous RSA study with a 10 years follow-up, retrospectively for n = 45 patients head&ndash;taper migration was calculated as the relative migration between femoral ball head and taper of the femoral stem using model-based RSA. A head&ndash;taper migration of 0.026 mm/year can be detected with available RSA technology. In vitro validation showed a total migration of 268 &plusmn; 11 &micro;m along the taper axis in a similar range to what has been reported using the RSA method. In vivo, a proof for interchangeable applicability of model-based RSA (EGS) and standard marker-based RSA methods was indicated by a significant deviation within the migration result after 12-month follow-up for all translation measurements, which was significantly correlated to the measured head&ndash;taper migration (r from 0.40 to 0.67; p < 0.05). The results identified that model-based RSA (EGS) could be used to detect head&ndash;taper migration in vivo and the measured movement could be validated in vitro and in vivo as well. Those findings supported the possibility of applying RSA for helping evaluate the head&ndash;taper corrosion related failure (trunnionosis).
DOI:doi:10.3390/ma13071543
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext ; Verlag: https://doi.org/10.3390/ma13071543
 Volltext: https://www.mdpi.com/1996-1944/13/7/1543
 DOI: https://doi.org/10.3390/ma13071543
Datenträger:Online-Ressource
Sprache:eng
Sach-SW:elementary geometrical shape model
 head-taper junction
 hip arthroplasty
 interchangeability
 migration
 Roentgen stereophotogrammetric analysis
K10plus-PPN:1698940785
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68581675   QR-Code
zum Seitenanfang