Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Faller, Friderike K. [VerfasserIn]   i
 Mein, Stewart [VerfasserIn]   i
 Ackermann, Benjamin [VerfasserIn]   i
 Debus, Jürgen [VerfasserIn]   i
 Stiller, Wolfram [VerfasserIn]   i
 Mairani, Andrea [VerfasserIn]   i
Titel:Pre-clinical evaluation of dual-layer spectral computed tomography-based stopping power prediction for particle therapy planning at the Heidelberg Ion Beam Therapy Center
Verf.angabe:Friderike K. Faller, Stewart Mein, Benjamin Ackermann, Jürgen Debus, Wolfram Stiller, Andrea Mairani
E-Jahr:2020
Jahr:24 April 2020
Umfang:14 S.
Fussnoten:Gesehen am 04.06.2020
Titel Quelle:Enthalten in: Physics in medicine and biology
Ort Quelle:Bristol : IOP Publ., 1956
Jahr Quelle:2020
Band/Heft Quelle:65(2020,9) Artikel-Nummer 095007, 14 Seiten
ISSN Quelle:1361-6560
Abstract:Accurate beam range prediction during clinical treatment planning is key to improve targeted dose delivery in proton and heavy ion therapy. A substantial source of beam range uncertainty is the prediction of ion stopping power ratio (SPR) relative to water from an empirical calibration based on conventional x-ray computed tomography (CT) used in clinical practice today. The aim of this study was to investigate the potential of a novel spectral CT imaging technique based on a dual-layer detector-based approach to improve the SPR prediction for particle therapy treatment planning, an improvement that would minimize the beam range uncertainty and allow for reduced safety margins in the patient. Using calibrated and validated maps of electron density and effective atomic number from spectral CT data, predicted SPR values in tissue substitutes were within a mean accuracy of 0.6% compared to measured SPR and showed substantially better agreement with measured data compared to standard CT-number-to-SPR calibration. The accuracy of SPR was not affected by CT acquisition settings, reconstruction parameters, phantom size, and type. Additionally, various spectral CT conversion algorithms were compared to determine the most accurate prediction method. Dosimetric validation of the developed method using a half-head anthropomorphic phantom in a routine-like setting indicated that SPR prediction with dual-layer spectral CT outperforms the clinical single-energy CT standard with a range prediction improvement of 1 mm. This study demonstrated in homogeneous and heterogeneous phantoms that spectral CT is feasible for particle therapy planning to improve range estimates for high-precision particle therapy.
DOI:doi:10.1088/1361-6560/ab735e
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext: https://doi.org/10.1088/1361-6560/ab735e
 DOI: https://doi.org/10.1088/1361-6560/ab735e
Datenträger:Online-Ressource
Sprache:eng
K10plus-PPN:1699787638
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68583902   QR-Code
zum Seitenanfang