Navigation überspringen
Universitätsbibliothek Heidelberg
Standort: ---
Exemplare: ---

+ Andere Auflagen/Ausgaben
heiBIB
 Online-Ressource
Verfasst von:Son, Hyeck Soo [VerfasserIn]   i
 Łabuz, Grzegorz [VerfasserIn]   i
 Khoramnia, Ramin [VerfasserIn]   i
 Merz, Patrick [VerfasserIn]   i
 Yildirim, Timur Mert [VerfasserIn]   i
 Auffarth, Gerd U. [VerfasserIn]   i
Titel:Ray propagation imaging and optical quality evaluation of different intraocular lens models
Verf.angabe:Hyeck Soo Son, Grzegorz Labuz, Ramin Khoramnia, Patrick Merz, Timur M. Yildirim, Gerd U. Auffarth
E-Jahr:2020
Jahr:February 4, 2020
Umfang:11 S.
Fussnoten:Gesehen am 15.06.2020
Titel Quelle:Enthalten in: PLOS ONE
Ort Quelle:San Francisco, California, US : PLOS, 2006
Jahr Quelle:2020
Band/Heft Quelle:15(2020,2) Artikel-Nummer e0228342, 11 Seiten
ISSN Quelle:1932-6203
Abstract:Purpose: Ray propagation visualization and optical performance analysis of four different intraocular lenses (IOLs) Methods In this laboratory study, four IOLs with different optical designs were assessed: a monofocal AcrySof IQ SN60WF [Alcon], a diffractive-refractive bifocal AcrySof IQ Restor SN6AD1 [Alcon], a diffractive trifocal AcrySof IQ PanOptix TFNT00 [Alcon], and a diffractive extended-depth-of-focus (EDOF) Symfony ZXR00 [Johnson&Johnson]. An experimental set-up with a water bath containing 0.01% fluorescein solution and monochromatic green laser light (532 nm) was used to visualize the propagation of light rays. Also, the optical performance of the IOLs was evaluated by measuring the modulation transfer function (MTF) values at a pupil sizes of 3.0 and 4.5 mm on the optical bench OptiSpheric® IOL PRO II (Trioptics GmbH, Germany). Results Both the diffractive-refractive bifocal IOL and the EDOF IOL showed two defined foci for distance and near vision. In the diffractive trifocal IOL, three distinct foci for distance, intermediate, and near vision could be visualized. Conclusions: The ray propagation visualization technique allows a qualitative assessment and comparison of light energy distribution between different IOL models. The measured Through-Focus Response (TFR) quantitatively confirmed the evaluated ray propagation behavior.
DOI:doi:10.1371/journal.pone.0228342
URL:kostenfrei: Volltext ; Verlag: https://dx.doi.org/10.1371/journal.pone.0228342
 kostenfrei: Volltext: https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0228342
 DOI: https://doi.org/10.1371/journal.pone.0228342
Datenträger:Online-Ressource
Sprache:eng
Bibliogr. Hinweis:Errata: Son, Hyeck Soo, 1991 - : Correction: Ray propagation imaging and optical quality evaluation of different intraocular lens models
Sach-SW:Artificial light
 Cornea
 Diffraction
 Eye lens
 Imaging techniques
 Lasers
 Optical lenses
 Optical materials
K10plus-PPN:1700577832
Verknüpfungen:→ Zeitschrift
 
 
Lokale URL UB: Zum Volltext

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68586761   QR-Code
zum Seitenanfang