| Online-Ressource |
Verfasst von: | Pahn, Gregor [VerfasserIn]  |
| Skornitzke, Stephan [VerfasserIn]  |
| Schlemmer, Heinz-Peter [VerfasserIn]  |
| Kauczor, Hans-Ulrich [VerfasserIn]  |
| Stiller, Wolfram [VerfasserIn]  |
Titel: | Toward standardized quantitative image quality (IQ) assessment in computed tomography (CT) |
Titelzusatz: | a comprehensive framework for automated and comparative IQ analysis based on ICRU Report 87 |
Verf.angabe: | Gregor Pahn, Stephan Skornitzke, Hans-Peter Schlemmer, Hans-Ulrich Kauczor, Wolfram Stiller |
Jahr: | 2016 |
Jahr des Originals: | 2015 |
Umfang: | 12 S. |
Fussnoten: | Available online 28 October 2015 ; Gesehen am 29.06.2020 |
Titel Quelle: | Enthalten in: Physica medica |
Ort Quelle: | Amsterdam : Elsevier, 1996 |
Jahr Quelle: | 2016 |
Band/Heft Quelle: | 32(2016), 1, Seite 104-115 |
ISSN Quelle: | 1724-191X |
Abstract: | Purpose - Based on the guidelines from “Report 87: Radiation Dose and Image-quality Assessment in Computed Tomography” of the International Commission on Radiation Units and Measurements (ICRU), a software framework for automated quantitative image quality analysis was developed and its usability for a variety of scientific questions demonstrated. - Methods - The extendable framework currently implements the calculation of the recommended Fourier image quality (IQ) metrics modulation transfer function (MTF) and noise-power spectrum (NPS), and additional IQ quantities such as noise magnitude, CT number accuracy, uniformity across the field-of-view, contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) of simulated lesions for a commercially available cone-beam phantom. Sample image data were acquired with different scan and reconstruction settings on CT systems from different manufacturers. - Results - Spatial resolution is analyzed in terms of edge-spread function, line-spread-function, and MTF. 3D NPS is calculated according to ICRU Report 87, and condensed to 2D and radially averaged 1D representations. Noise magnitude, CT numbers, and uniformity of these quantities are assessed on large samples of ROIs. Low-contrast resolution (CNR, SNR) is quantitatively evaluated as a function of lesion contrast and diameter. Simultaneous automated processing of several image datasets allows for straightforward comparative assessment. - Conclusions - The presented framework enables systematic, reproducible, automated and time-efficient quantitative IQ analysis. Consistent application of the ICRU guidelines facilitates standardization of quantitative assessment not only for routine quality assurance, but for a number of research questions, e.g. the comparison of different scanner models or acquisition protocols, and the evaluation of new technology or reconstruction methods. |
DOI: | doi:10.1016/j.ejmp.2015.09.017 |
URL: | Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.
Volltext ; Verlag: https://doi.org/10.1016/j.ejmp.2015.09.017 |
| Volltext: http://www.sciencedirect.com/science/article/pii/S1120179715010030 |
| DOI: https://doi.org/10.1016/j.ejmp.2015.09.017 |
Datenträger: | Online-Ressource |
Sprache: | eng |
Sach-SW: | Computed tomography (CT) |
| Modulation transfer function (MTF) |
| Noise-power spectrum (NPS) |
| Quantitative image quality assessment |
K10plus-PPN: | 1702839575 |
Verknüpfungen: | → Zeitschrift |
Toward standardized quantitative image quality (IQ) assessment in computed tomography (CT) / Pahn, Gregor [VerfasserIn]; 2016 (Online-Ressource)