| Online-Ressource |
Verfasst von: | Vardag, Sanam Noreen [VerfasserIn]  |
| Hammer, Samuel [VerfasserIn]  |
| Sabasch, Michael [VerfasserIn]  |
| Levin, Ingeborg [VerfasserIn]  |
Titel: | First continuous measurements of δ18O-CO2 in air with a Fourier transform infrared spectrometer |
Verf.angabe: | S. N. Vardag, S. Hammer, M. Sabasch, D.W.T. Griffith, and I. Levin |
E-Jahr: | 2015 |
Jahr: | 4 February 2015 |
Umfang: | 14 S. |
Teil: | volume:8 |
| year:2015 |
| number:2 |
| pages:579-592 |
| extent:14 |
Fussnoten: | Im Titel ist Delta als griechischer Buchstabe dargestellt ; Im Titel ist die 18 hochgestellt und die 2 tiefgestellt ; Gesehen am 08.07.2020 |
Titel Quelle: | Enthalten in: Atmospheric measurement techniques discussions |
Ort Quelle: | Katlenburg-Lindau : Copernicus, 2008 |
Jahr Quelle: | 2015 |
Band/Heft Quelle: | 8(2015), 2, Seite 579-592 |
ISSN Quelle: | 1867-8610 |
Abstract: | The continuous in situ measurement of δ<sup>18</sup>O in atmospheric CO<sub>2</sub> opens a new door to differentiating between CO<sub>2</sub> source and sink components with high temporal resolution. Continuous <sup>13</sup>C-CO<sub>2</sub> measurement systems have already been commercially available for some time, but until now, only few instruments have been able to provide a continuous measurement of the oxygen isotope ratio in CO<sub>2</sub>. Besides precise <sup>13</sup>C/<sup>12</sup>C observations, the Fourier transform infrared (FTIR) spectrometer is also able to measure the <sup>18</sup>O / <sup>16</sup>O ratio in CO<sub>2</sub>, but the precision and accuracy of the measurements have not yet been evaluated. Here we present a first analysis of δ<sup>18</sup>O-CO<sub>2</sub> (and δ<sup>13</sup>C-CO<sub>2</sub>) measurements with the FTIR analyser in Heidelberg. We used Allan deviation to determine the repeatability of δ<sup>18</sup>O-CO<sub>2</sub> measurements and found that it decreases from 0.25‰ for 10 min averages to about 0.1‰ after 2 h and remains at that value up to 24 h. We evaluated the measurement precision over a 10-month period (intermediate measurement precision) using daily working gas measurements and found that our spectrometer measured δ<sup>18</sup>O-CO<sub>2</sub> to better than 0.3‰ at a temporal resolution of less than 10 min. The compatibility of our FTIR-spectrometric measurements to isotope-ratio mass-spectrometric (IRMS) measurements was determined by comparing FTIR measurements of cylinder gases and ambient air with IRMS measurements of flask samples, filled with gases of the same cylinders or collected from the same ambient air intake. Two-sample <i>t</i> tests revealed that, at the 0.01 significance level, the FTIR and the IRMS measurements do not differ significantly from each other and are thus compatible. We describe two weekly episodes of ambient air measurements, one in winter and one in summer, and discuss what potential insights and new challenges combined highly resolved CO<sub>2</sub>, δ<sup>13</sup>C-CO<sub>2</sub> and δ<sup>18</sup>O-CO<sub>2</sub> records may provide in terms of better understanding regional scale continental carbon exchange processes.</p> |
DOI: | doi:10.5194/amt-8-579-2015 |
URL: | Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.
Volltext ; Verlag: https://doi.org/https://doi.org/10.5194/amt-8-579-2015 |
| Volltext: https://www.atmos-meas-tech.net/8/579/2015/ |
| DOI: https://doi.org/10.5194/amt-8-579-2015 |
Datenträger: | Online-Ressource |
Sprache: | eng |
K10plus-PPN: | 1713899051 |
Verknüpfungen: | → Zeitschrift |
First continuous measurements of δ18O-CO2 in air with a Fourier transform infrared spectrometer / Vardag, Sanam Noreen [VerfasserIn]; 4 February 2015 (Online-Ressource)