Titel:Accuracy of laser-melted patient-specific implants in genioplasty
Titelzusatz:a three-dimensional retrospective study
Verf.angabe:Thomas Rückschloß, Oliver Ristow, Reinald Kühle, Frederic Weichel, Christoph Roser, Kerstin Aurin, Michael Engel, Jürgen Hoffmann, Christian Freudlsperger
E-Jahr:2020
Jahr:19 May 2020
Umfang:8 S.
Fussnoten:Gesehen am 21.07.2020
Titel Quelle:Enthalten in: Journal of cranio-maxillofacial surgery
Ort Quelle:Oxford [u.a.] : Elsevier, 1987
Jahr Quelle:2020
Band/Heft Quelle:48(2020), 7, Seite 653-660
ISSN Quelle:1878-4119
Abstract:Purpose - To assess the accuracy of laser-melted patient-specific implants (PSI) with regard to a preoperative virtual treatment plan for genioplasty based on a new analysis method without the use of landmarks. - Materials and methods - A retrospective evaluation of a cohort of Class II and Class III patients who had undergone virtually planned orthognathic surgery (including genioplasty) was carried out. The preoperative virtual treatment plan and the postoperative outcome were fused to calculate the translational and rotational discrepancies between the 3D planning and the actual surgical outcome. - Results - The accuracy of left/right positioning was 0.25 ± 0.28 mm (p < 0.001), that of anterior/posterior positioning was 0.70 ± 0.64 mm (p < 0.001), and that of up/down-positioning was 0.45 ± 0.38 mm (p < 0.001). The rotational discrepancies were less than 2 deg. The virtually planned and postoperative positions of the chin differed significantly from each other (p < 0.001 for all rotational and translational discrepanices). - Conclusion - The findings demonstrate that PSIs can transfer the planned virtual genioplasty into the operation theatre with small but significant deviations. However, since no conclusions can be drawn from the results regarding surgical success in terms of shaping the soft tissue profile as well as the esthetic result, no superiority of PSI over traditional plate osteosynthesis can be demonstrated.
DOI:doi:10.1016/j.jcms.2020.05.003
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext: https://doi.org/10.1016/j.jcms.2020.05.003
 Volltext: http://www.sciencedirect.com/science/article/pii/S1010518220301141
 DOI: https://doi.org/10.1016/j.jcms.2020.05.003
Datenträger:Online-Ressource
Sprache:eng
Sach-SW:Genioplasty
 Orthognathic surgery
 Patient-specific implant
 Virtual planning
K10plus-PPN:1725235293
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68618986   QR-Code
zum Seitenanfang