Titel:Influence of weight and structure on biological behavior of polypropylene mesh prostheses placed at the esophageal hiatus
Verf.angabe:Jonas Senft, Tobias Gehrig, Felix Lasitschka, Georg R. Linke, Maxym Shevchenko, Thomas Bruckner, Hannes G. Kenngott, Lars Fischer, and Beat P. Müller-Stich
E-Jahr:2014
Jahr:10 June 2014
Umfang:8 S.
Fussnoten:Gesehen am 14.08.2020
Titel Quelle:Enthalten in: Journal of laparoendoscopic & advanced surgical techniques
Ort Quelle:New York, NY : Liebert, 1997
Jahr Quelle:2014
Band/Heft Quelle:24(2014), 6, Seite 383-390
ISSN Quelle:1557-9034
Abstract:Background: Experimental knowledge about mesh behavior at the esophageal hiatus is rare, but such information is essential in order to find a safe and effective method of mesh reinforcement. This study aimed to investigate the influence of mesh structure on the biological behavior of polypropylene prostheses placed at the hiatus.Materials and Methods: Twenty-four pigs in three groups of eight underwent implantation of heavyweight small-porous (HW-SP), heavyweight large-porous (HW-LP), or lightweight large-porous (LW-LP) circular polypropylene mesh at the hiatus. Eight weeks later, the meshes were explanted. Macroscopic analysis was performed evaluating mesh deformation, adhesions, and position relative to the hiatal margin. Histological analysis comprised evaluation of foreign body reaction and tissue integration by mononuclear cell count and immunostaining of Ki-67, collagen type I, and collagen type III.Results: No mesh-related complications occurred. Mesh shrinkage was observed within all groups and was the lowest for HW-LP, higher for HW-SP, and highest for LW-LP (13.8% versus 19.5% versus 25.5%; P<.001). The adhesion score was highest for HW-SP, lower for HW-LP, and lowest for LW-LP (11.0 versus 8.0 versus 6.0; P<.001). The collagen type I/III ratio was higher for HW-SP compared with HW-LP and LW-LP (3.1 versus 2.2 versus 1.8; P=.014).Conclusions: Heavyweight polypropylene meshes may be advantageous for application at the hiatus. They provide a solid fixation of the esophagogastric junction by adhesions, which may contribute to a reduction of hernia recurrence. In heavyweight meshes, the large-porous structure is associated with superior form stability, and small-porous meshes are superior with regard to solidity of tissue integration, which may prevent mesh migration.
DOI:doi:10.1089/lap.2013.0588
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext: https://doi.org/10.1089/lap.2013.0588
 Volltext: https://www.liebertpub.com/doi/10.1089/lap.2013.0588
 DOI: https://doi.org/10.1089/lap.2013.0588
Datenträger:Online-Ressource
Sprache:eng
K10plus-PPN:1727090217
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68627571   QR-Code
zum Seitenanfang