Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Cotter, Brendan D. [VerfasserIn]   i
 Innmann, Moritz Maximilian [VerfasserIn]   i
 Dobransky, Johanna S. [VerfasserIn]   i
 Merle, Christian [VerfasserIn]   i
 Beaulé, Paul E. [VerfasserIn]   i
 Grammatopoulos, George [VerfasserIn]   i
Titel:Does functional cup orientation change at minimum of 10 years after primary total hip arthroplasty?
Verf.angabe:Brendan D. Cotter, Msc, Moritz M. Innmann, MD, Johanna S. Dobransky, MHK, Christian Merle, MD, PhD, MSc, Paul E. Beaulé, MD, FRCSC, George Grammatopoulos, FRCS (Tr & Ortho), DPhil (Oxon)
E-Jahr:2020
Jahr:28 April 2020
Umfang:6 S.
Fussnoten:Gesehen am 14.09.2020
Titel Quelle:Enthalten in: The journal of arthroplasty
Ort Quelle:Orlando, Fla. : Churchill Livingstone, 1986
Jahr Quelle:2020
Band/Heft Quelle:35(2020), 9, Seite 2507-2512
ISSN Quelle:1532-8406
Abstract:Background - Cup orientation has been shown to influence the postoperative risk of impingement and dislocation following total hip arthroplasty (THA) and may change over time due to changes in pelvic tilt that occur with aging. The purpose of this study is to determine if there is a significant change in acetabular cup inclination and anteversion over a 10-year period following THA. - Methods - A retrospective, multisurgeon, single-center cohort study was conducted of 46 patients that underwent THA between 1995 and 2002. A total of 46 patients were included, with a median age at surgery of 56 years, and a median time between initial postoperative radiograph and the most recent one being 13.5 years (minimum 10 years). Cup orientation was measured from postoperative and follow-up supine anterior-posterior pelvic radiographs. Using a validated software, inclination and anteversion were calculated at each interval and the change in cup anteversion and inclination angle was determined. Furthermore, the difference in the sacro-femoral-pubic angle was measured, reflecting the difference in pelvic tilt between intervals. - Results - No significant difference was detected between measurements taken from initial postoperative radiograph and measurements a minimum of 10 years later (P > .45), with the median (interquartile range) change in anteversion, inclination, and sacro-femoral-pubic being 0° (−1° to 3°), 1° (−3° to 2°), and 0° (−2° to 3°), respectively. - Conclusion - Our study found no significant change in functional cup orientation a minimum of 10 years after THA. No shifts in functional cup orientation as a result of altering spinopelvic alignment seemed to be present over a 10-year period.
DOI:doi:10.1016/j.arth.2020.04.075
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext ; Verlag: https://doi.org/10.1016/j.arth.2020.04.075
 Volltext: http://www.sciencedirect.com/science/article/pii/S0883540320304630
 DOI: https://doi.org/10.1016/j.arth.2020.04.075
Datenträger:Online-Ressource
Sprache:eng
Sach-SW:alignment
 cup orientation
 pelvic tilt
 spinopelvic
 total hip arthroplasty
K10plus-PPN:1731813619
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68637109   QR-Code
zum Seitenanfang