Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Leutz-Schmidt, Patricia [VerfasserIn]   i
 Wielpütz, Mark Oliver [VerfasserIn]   i
 Skornitzke, Stephan [VerfasserIn]   i
 Weinheimer, Oliver [VerfasserIn]   i
 Kauczor, Hans-Ulrich [VerfasserIn]   i
 Puderbach, Michael [VerfasserIn]   i
 Pahn, Gregor [VerfasserIn]   i
 Stiller, Wolfram [VerfasserIn]   i
Titel:Influence of acquisition settings and radiation exposure on CT lung densitometry—An anthropomorphic ex vivo phantom study
Verf.angabe:Patricia Leutz-Schmidt, Mark O. Wielpütz, Stephan Skornitzke, Oliver Weinheimer, Hans-Ulrich Kauczor, Michael U. Puderbach, Gregor Pahn, Wolfram Stiller
E-Jahr:2020
Jahr:August 14, 2020
Umfang:13 S.
Fussnoten:Gesehen am 24.09.2020
Titel Quelle:Enthalten in: PLOS ONE
Ort Quelle:San Francisco, California, US : PLOS, 2006
Jahr Quelle:2020
Band/Heft Quelle:15(2020,8) Artikel-Nummer e0237434, 13 Seiten
ISSN Quelle:1932-6203
Abstract:Objectives To systematically evaluate the influence of acquisition settings in conjunction with raw-data based iterative image reconstruction (IR) on lung densitometry based on multi-row detector computed tomography (CT) in an anthropomorphic chest phantom. Materials and methods Ten porcine heart-lung explants were mounted in an ex vivo chest phantom shell, six with highly and four with low attenuating chest wall. CT (Somatom Definition Flash, Siemens Healthineers) was performed at 120kVp and 80kVp, each combined with current-time products of 120, 60, 30, and 12mAs, and was reconstructed with filtered back projection (FBP) and IR (Safire, Siemens Healthineers). Mean lung density (LD), air density (AD) and noise were measured by semi-automated region-of interest (ROI) analysis, with 120kVp/120 mAs serving as the standard of reference. Results Using IR, noise in lung parenchyma was reduced by ~ 31% at high attenuating chest wall and by ~ 22% at low attenuating chest wall compared to FBP, respectively (p<0.05). IR induced changes in the order of ±1 HU to mean absolute LD and AD compared to corresponding FBP reconstructions which were statistically significant (p<0.05). Conclusions Densitometry is influenced by acquisition parameters and reconstruction algorithms to a degree that may be clinically negligible. However, in longitudinal studies and clinical research identical protocols and potentially other measures for calibration may be required.
DOI:doi:10.1371/journal.pone.0237434
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext ; Verlag: https://doi.org/10.1371/journal.pone.0237434
 Volltext: https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0237434
 DOI: https://doi.org/10.1371/journal.pone.0237434
Datenträger:Online-Ressource
Sprache:eng
Sach-SW:Computed axial tomography
 Data acquisition
 Densitometry
 Infrared radiation
 Noise reduction
 Pulmonary imaging
 Radiation exposure
 Thoracic diaphragm
K10plus-PPN:1733674365
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68640084   QR-Code
zum Seitenanfang