Titel:Evaluation of samplers and filter materials for the establishment of trace metal concentration profiles in peat bog porewaters using inductively coupled plasma-mass spectrometry
Verf.angabe:Nicole Rausch, Liisa Ukonmaanaho, Tiina M. Nieminen, Michael Krachler, Gaël Le Roux, William Shotyk
Jahr:2006
Umfang:10 S.
Fussnoten:Available online 20 December 2005 ; Gesehen am 29.09.2020
Titel Quelle:Enthalten in: Analytica chimica acta
Ort Quelle:Amsterdam : Elsevier Science, 1947
Jahr Quelle:2006
Band/Heft Quelle:558(2006), 1, Seite 201-210
ISSN Quelle:1873-4324
Abstract:Two different types of sampler were used for the collection of humic-rich porewaters from ombrotrophic bogs at background and contaminated sites: a syringe-type sampler, which required manual filtration and dialysis chambers (peepers) where samples were filtered in situ. Concentrations of 10 trace elements Cd, Co, Cr, Cu, Mn, Mo, Ni, Pb, V and Zn have been determined in the collected porewater samples using inductively coupled plasma-sector-field-mass spectrometry. The accuracy of the analytical procedures was evaluated by the regular analyses of the two certified riverine water reference materials SLRS-2 and SLRS-4, respectively. For the syringe-type sampler, four different 0.45μm syringe filters were tested. Low blank values together with sufficiently low filtration artefacts were obtained using unwashed GD/XP filters (Whatman). When pre-cleaned filters were used, Cu and Mo showed strong filtration artefacts. Mean metal concentrations of filtrates differed by up to five times, depending on the filter type used. Overall blank values of the sampling devices were as follows (ngl−1): Cd 1, Co 9, Cr 50, Cu 70, Mn 200, Mo 20, Ni 100, Pb 4, V 10, Zn 1000. The contribution of atmospheric dust during the on-site filtration might have enhanced overall blank levels of Cr, Cu and Zn when protective covers were not used during sample collection/on-site filtration. Metal concentrations at background sites were at ngl−1 levels except for Zn and Mn (low μgl−1). With the exception of Co and Mn, dialysis chambers were not suitable for sampling porewaters at these concentration levels.
DOI:doi:10.1016/j.aca.2005.11.037
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext: https://doi.org/10.1016/j.aca.2005.11.037
 Volltext: http://www.sciencedirect.com/science/article/pii/S0003267005018969
 DOI: https://doi.org/10.1016/j.aca.2005.11.037
Datenträger:Online-Ressource
Sprache:eng
Sach-SW:ICP-MS
 Porewater
 Sample collection
 Trace metals
K10plus-PPN:1733914927
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68641183   QR-Code
zum Seitenanfang