Status: Bibliographieeintrag
Standort: ---
Exemplare:
---
| Online-Ressource |
Verfasst von: | Lattard, Dominique [VerfasserIn]  |
| Sauerzapf, Ursula [VerfasserIn]  |
| Käsemann, Martin [VerfasserIn]  |
Titel: | New calibration data for the Fe-Ti oxide thermo-oxybarometers from experiments in the Fe-Ti-O system at 1 bar, 1,000-1,300°C and a large range of oxygen fugacities |
Verf.angabe: | Dominique Lattard, Ursula Sauerzapf, Martin Käsemann |
E-Jahr: | 2005 |
Jahr: | 7 June 2005 |
Umfang: | 20 S. |
Fussnoten: | Gesehen am 06.10.2020 |
Titel Quelle: | Enthalten in: Contributions to mineralogy and petrology |
Ort Quelle: | Berlin : Springer, 1947 |
Jahr Quelle: | 2005 |
Band/Heft Quelle: | 149(2005), 6, Seite 735-754 |
ISSN Quelle: | 1432-0967 |
Abstract: | The current formulations of the Fe-Ti oxide thermobarometer (titanomagnetite-ilmenitess) fail to reproduce experimental results, in particular at the high temperatures that are relevant for basaltic assemblages. With the aim of improving the experimental basis of the calibration in the Fe-Ti-O system, we have synthesised assemblages of titanomagnetite-ilmenitess (Tmt-Ilmss), ilmenitess-pseudobrookitess (Ilmss-Psbss) and single-phase samples under a wide range of fO2 (fixed with CO/CO2 mixtures or by solid oxygen buffers) in sub-solidus conditions (1,000-1,300°C) at 1 bar. Runs lasted ≥24 h at 1,300°C and up to 240 h at 1,000°C and were terminated by quenching in water. All run products are polycrystalline, roughly equigranular aggregates, with grain sizes of 10-50 μm. They were examined and analysed with the SEM and EMP. Tmt compositions are broadly in accordance with the current models at moderate fO2, but significantly richer in Ti at low fO2 and high T, due to cationic vacancies. Ilmss compositions depart from the predicted values practically at all fO2 and T conditions, which is related to unsatisfactory thermodynamic models for the rhombohedral oxide. For Ilmss-Psbss assemblages the best agreement between our data and current calculations is at 1,000°C and moderately high fO2. Otherwise, experimental and calculated data strongly disagree. The experimental data set on the three Fe-Ti oxide solid solutions presented here is intended to support new versions of both the titanomagnetite-ilmenitess thermo-oxybarometer and the ilmenitess-pseudobrookitess oxybarometer. |
DOI: | doi:10.1007/s00410-005-0679-2 |
URL: | Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.
Volltext: https://doi.org/10.1007/s00410-005-0679-2 |
| DOI: https://doi.org/10.1007/s00410-005-0679-2 |
Datenträger: | Online-Ressource |
Sprache: | eng |
K10plus-PPN: | 1734773820 |
Verknüpfungen: | → Zeitschrift |
New calibration data for the Fe-Ti oxide thermo-oxybarometers from experiments in the Fe-Ti-O system at 1 bar, 1,000-1,300°C and a large range of oxygen fugacities / Lattard, Dominique [VerfasserIn]; 7 June 2005 (Online-Ressource)
68643540