| Online-Ressource |
Verfasst von: | Benveniste, Glen L. [VerfasserIn]  |
| Tjahjono, Richard [VerfasserIn]  |
| Cheng, Oliver [VerfasserIn]  |
| Verhagen, Hence J. M. [VerfasserIn]  |
| Böckler, Dittmar [VerfasserIn]  |
| Varcoe, Ramon L. [VerfasserIn]  |
Titel: | Long-term results of 180 consecutive patients with abdominal aortic aneurysm treated with the endurant stent graft system |
Verf.angabe: | Glen L. Benveniste, Richard Tjahjono, Oliver Chen, Hence J. M. Verhagen, Dittmar Böckler, Ramon L. Varcoe |
E-Jahr: | 2020 |
Jahr: | 20 March 2020 |
Umfang: | 9 S. |
Fussnoten: | Gesehen am 15.10.2020 |
Titel Quelle: | Enthalten in: Annals of vascular surgery |
Ort Quelle: | Orlando, Fla. : Elsevier, 1986 |
Jahr Quelle: | 2020 |
Band/Heft Quelle: | 67(2020), Seite 265-273 |
ISSN Quelle: | 1615-5947 |
Abstract: | Background - Registry studies have shown that the Endurant stent graft is associated with low rates of all-cause and aneurysm-related mortality when used for the endovascular treatment of abdominal aortic aneurysm (AAA). However, many were limited by length of follow-up and all had a proportion of patients lost to follow-up. The aim of this study is to report results from a large, real-world experience using Endurant, utilizing methods to ensure complete ascertainment of mortality. - Methods - This study describes a large, single vascular unit experience using the Endurant stent graft in consecutive patients treated between August 2008 and March 2019. - Results - One-hundred eighty patients (mean age 76.0 ± 8.6 years; 90% male) with mean AAA diameter of 57.5 ± 10.5 mm underwent endovascular aneurysm repair (EVAR). Technical success was achieved in all cases. At median follow-up of 55.0 months (interquartile range 29.8-79.0), 51 (28.3%) patients had died. Kaplan-Meier estimate of 5-year overall survival and freedom from aneurysm-related death was 71.6% and 99.4%, respectively. Lower survival rates were observed in patients who underwent EVAR at age ≥80 years (59.2% vs. 78.3%, P < 0.01) and with aneurysm diameter ≥70 mm (55.6% vs. 73.8%, P = 0.03). Thirteen endoleaks (7.2%; 4 type 1A, 2 type 1B, 7 type 2) were observed during follow-up (mean time from implantation 8.7 ± 4.2, range 1-52 months). Eleven patients (6.1%) required secondary intervention for limb occlusion (n = 7), endoleak (n = 3), and restenosis (n = 1). Patients treated within (n = 104; 57.8%) and outside (n = 76; 42.2%) the manufacturer’s instructions for use (IFU) had similar rates of endoleak (7 [6.7%] vs. 6 [7.9%]; P = 0.76), secondary re-intervention (7 [6.7%] vs. 4 [5.3%]; P = 0.74) and overall-survival (72 [69.2%] vs. 55 [72.3%]; P = 0.46). - Conclusions - Results from this real-world study of consecutive patients treated for AAA using the Endurant stent graft demonstrate that it is safe and effective, with excellent long-term outcomes for anatomy that falls both inside and outside IFU recommendations. |
DOI: | doi:10.1016/j.avsg.2020.02.020 |
URL: | Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.
Volltext: https://doi.org/10.1016/j.avsg.2020.02.020 |
| Volltext: http://www.sciencedirect.com/science/article/pii/S089050962030220X |
| DOI: https://doi.org/10.1016/j.avsg.2020.02.020 |
Datenträger: | Online-Ressource |
Sprache: | eng |
K10plus-PPN: | 1735640387 |
Verknüpfungen: | → Zeitschrift |
Long-term results of 180 consecutive patients with abdominal aortic aneurysm treated with the endurant stent graft system / Benveniste, Glen L. [VerfasserIn]; 20 March 2020 (Online-Ressource)