Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Auffarth, Gerd U. [VerfasserIn]   i
 Reddy, Kasu Prasad [VerfasserIn]   i
 Ritter, Roland [VerfasserIn]   i
 Holzer, Mike P. [VerfasserIn]   i
 Rabsilber, Tanja Marina [VerfasserIn]   i
Titel:Comparison of the maximum applicable stretch force after femtosecond laser-assisted and manual anterior capsulotomy
Verf.angabe:Gerd U. Auffarth, MD, PhD, FEBO, Kasu Prasad Reddy, MD, Roland Ritter, MSc, Mike P. Holzer, MD, FEBO, Tanja M. Rabsilber, MD
Jahr:2013
Umfang:5 S.
Fussnoten:Gesehen am 22.10.2020 ; First published: 12 December 2012
Titel Quelle:Enthalten in: Journal of cataract and refractive surgery
Ort Quelle:Fairfax, Va. : Soc., 1986
Jahr Quelle:2013
Band/Heft Quelle:39(2013), 1, Seite 105-109
ISSN Quelle:1873-4502
Abstract:Purpose: To objectively measure the strength of the capsulotomy performed with a femtosecond laser-assisted technique or performed manually in a pig-eye laboratory study. - Setting - International Vision Correction Research Centre, Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany. - Design - Experimental study. - Methods - Ten fresh pig eyes were randomly assigned to femtosecond laser-assisted capsulotomy or manual capsulotomy. The capsule was immersed in hyaluronic acid, and retractors were fixed in the capsule opening with a pull-force measuring device. The force necessary to break the capsulotomy was measured in millinewtons (mN); the maximum stretching ratio was also assessed. - Results - The observed mean rupture force (ie, maximum amount of force measured immediately before tissue rupture) was 113 mN ± 12 (SD) in the laser-assisted procedure and 73 ± 22 mN in the manual procedure (P<.05). The stretching ratios were 1.60 ± 0.10 (femtosecond) and 1.35 ± 0.04 (manual) (P<.05). - Conclusion - In this laboratory pig-eye study, femtosecond laser-assisted capsulotomy resulted in a significantly stronger anterior capsule opening than the standard manually performed capsulotomy. - Financial Disclosure - Drs. Auffarth, Reddy, and Holzer have received research and travel grants from Technolas Perfect Vision GmbH. Mr. Ritter is an employee of Technolas Perfect Vision GmbH, Munich, Germany.
DOI:doi:10.1016/j.jcrs.2012.08.065
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext: https://doi.org/10.1016/j.jcrs.2012.08.065
 Volltext: https://journals.lww.com/jcrs/Abstract/2013/01000/Comparison_of_the_maximum_applicable_stretch_force.17.aspx
 DOI: https://doi.org/10.1016/j.jcrs.2012.08.065
Datenträger:Online-Ressource
Sprache:eng
K10plus-PPN:1736254367
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68652875   QR-Code
zum Seitenanfang