Titel:Performance of the LHCb Outer Tracker
Körperschaft:LHCb Collaboration [VerfasserIn]   i
Verf.angabe:the LHCb Outer Tracker group
E-Jahr:2014
Jahr:January 7, 2014
Fussnoten:The LHCb Outer Tracker group: R. Arink, S. Bachmann, Y. Bagaturia, H. Band, Th. Bauer, A. Berkien, Ch. Färber, A. Bien, J. Blouw, L. Ceelie, V. Coco, M. Deckenhoff, Z. Deng, F. Dettori, D. van Eijk, R. Ekelhof, E. Gersabeck, L. Grillo, W.D. Hulsbergen, T.M. Karbach, R. Koopman, A. Kozlinskiy, Ch. Langenbruch, V. Lavrentyev, Ch. Linn, M. Merk, J. Merkel, M. Meissner, J. Michalowski, P. Morawski, A. Nawrot, M. Nedos, A. Pellegrino, G. Polok, O. van Petten, J. Rövekamp, F. Schimmel, H. Schuylenburg, R. Schwemmer, P. Seyfert, N. Serra, T. Sluijk, B. Spaan, J. Spelt, B. Storaci, M. Szczekowski, S. Swientek, S. Tolk, N. Tuning, U. Uwer, D. Wiedner, M. Witek, M. Zeng, A. Zwart ; Gesehen am 02.11.2020
Titel Quelle:Enthalten in: Journal of Instrumentation
Ort Quelle:London : Inst. of Physics, 2006
Jahr Quelle:2014
Band/Heft Quelle:9(2014) Artikel-Nummer P01002, 28 Seiten
ISSN Quelle:1748-0221
Abstract:The LHCb Outer Tracker is a gaseous detector covering an area of 5 × 6 m2 with 12 double layers of straw tubes. The detector with its services are described together with the commissioning and calibration procedures. Based on data of the first LHC running period from 2010 to 2012, the performance of the readout electronics and the single hit resolution and efficiency are presented. The efficiency to detect a hit in the central half of the straw is estimated to be 99.2%, and the position resolution is determined to be approximately 200 μm. The Outer Tracker received a dose in the hottest region corresponding to 0.12 C/cm, and no signs of gain deterioration or other ageing effects are observed.
DOI:doi:10.1088/1748-0221/9/01/P01002
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext: https://doi.org/10.1088/1748-0221/9/01/P01002
 DOI: https://doi.org/10.1088/1748-0221/9/01/P01002
Datenträger:Online-Ressource
Sprache:eng
K10plus-PPN:1737512920
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68656035   QR-Code
zum Seitenanfang