Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Mayer, Christian [VerfasserIn]   i
 Son, Hyeck Soo [VerfasserIn]   i
 Łabuz, Grzegorz [VerfasserIn]   i
 Yildirim, Timur Mert [VerfasserIn]   i
 Auffarth, Gerd U. [VerfasserIn]   i
 Khoramnia, Ramin [VerfasserIn]   i
Titel:In vitro optical quality assessment of a monofocal IOL sutured to an artificial iris
Verf.angabe:Christian Mayer, Hyeck-Soo Son, Grzegorz Labuz, Timur M. Yildirim, Gerd U. Auffarth, Ramin Khoramnia
Jahr:2020
Umfang:5 S.
Fussnoten:Gesehen am 09.11.2020
Titel Quelle:Enthalten in: Journal of cataract and refractive surgery
Ort Quelle:Fairfax, Va. : Soc., 1986
Jahr Quelle:2020
Band/Heft Quelle:46(2020), 8, Seite 1184-1188
ISSN Quelle:1873-4502
Abstract:Purpose: To assess whether the combined implantation of a monofocal IOL and an artificial iris had an effect on the IOL's optical performance. - Setting: David J. Apple International Laboratory for Ocular Pathology, Heidelberg, Germany. - Design: In vitro laboratory study. - Methods: IOL optical quality was assessed using an OptiSpheric IOL Pro II to measure the IOL's modulation transfer function (MTF) at 3.0 mm pupil size and spatial frequency of 100 lp/mm. Three ASPIRA-aAY IOLs with different base powers, 10.0 diopter (D) (IOL A), 20.0 D (IOL B), and 30.0 D (IOL C) were measured before and after suturing the IOL to an ArtificialIris (AI). The degree of IOL decentration about the center of the AI was also evaluated. - Results: The mean MTF values prior to suturing were 0.57, 0.65, and 0.63 for IOLs A, B, and C, respectively. After suturing to the AI, the mean MTF values were 0.52, 0.54, and 0.55 for IOLs A, B, and C, respectively. The decentration values in vertical direction were 0.20 mm, 0.00 mm, and 0.02 mm for IOLs A, B, and C, respectively. In horizontal direction, the decentration values were 0.42 mm, 0.10 mm, and 0.03 mm for IOLs A, B, and C, respectively. - Conclusions: The MTF decreased slightly in all 3 IOLs after they were sutured to the AI. The small differences, however, should be clinically irrelevant. This laboratory assessment showed that suturing of the IOL to the AI can be performed in a reliable and reproducible manner without deteriorating optical quality.
DOI:doi:10.1097/j.jcrs.0000000000000287
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext: https://doi.org/10.1097/j.jcrs.0000000000000287
 Volltext: https://journals.lww.com/jcrs/Abstract/2020/08000/In_vitro_optical_quality_assessment_of_a_monofocal.19.aspx
 DOI: https://doi.org/10.1097/j.jcrs.0000000000000287
Datenträger:Online-Ressource
Sprache:eng
K10plus-PPN:1738225968
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68658810   QR-Code
zum Seitenanfang