Titel:Trifocality achieved through polypseudophakia
Titelzusatz:optical quality and light loss compared with a single trifocal intraocular lens
Verf.angabe:Grzegorz Łabuz, PhD; Gerd U. Auffarth, MD, PhD; Michael C. Knorz, MD, PhD; Hyeck-Soo Son, MD; Timur M. Yildirim, MD; Ramin Khoramnia, MD, PhD
E-Jahr:2020
Jahr:Sep 2020
Umfang:8 S.
Fussnoten:Gesehen am 12.11.2020
Titel Quelle:Enthalten in: Journal of refractive surgery
Ort Quelle:Thorofare, NJ : SLACK Inc., 1996
Jahr Quelle:2020
Band/Heft Quelle:36(2020), 9, Seite 570-577
ISSN Quelle:1938-2391
Abstract:PURPOSE: To compare the optical performance of a two-intraocular lens (IOL) system with that of a single capsular bag trifocal IOL. METHODS: The two-IOL configuration of a monofocal RayOne Aspheric (Rayner Intraocular Lenses, Ltd) and a Sulcoflex Trifocal (Rayner Intraocular Lenses, Ltd) lens was compared in vitro with a single-lens option (RayOne Trifocal; Rayner Intraocular Lenses, Ltd). Two samples of each IOL model were studied with an optical metrology device. The optical quality was assessed using the area under the modulation transfer function (MTF). The impact of the supplementary lens misalignment on the MTF was tested. The light loss was also measured using a power meter. RESULTS: The two-IOL system produced three well-defined focal peaks comparable to those of the single lens. The MTF area of the single- and two-IOL configuration was, respectively, 22.5 and 20.7 at far, 16.4 and 15.4 at intermediate, and 14.9 for each configuration at near. A moderate decentration (up to 0.6 mm) had a minimal effect at intermediate and near on the supplementary lens MTF and no impact at far. A 5 degrees tilt did not alter the MTF. The supplementary tens caused a 1.3% decrease in the optical power. CONCLUSIONS: The optical quality of the two-IOL system matched that of the single trifocal lens. A tow-power supplementary IOL demonstrated high tolerance to misalignment and minimal light attenuation. The reversibility of the two-IOL approach may prove advantageous clinically.
DOI:doi:10.3928/1081597X-20200715-01
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext: https://doi.org/10.3928/1081597X-20200715-01
 DOI: https://doi.org/10.3928/1081597X-20200715-01
Datenträger:Online-Ressource
Sprache:eng
Sach-SW:bag
 depth-of-focus
 extended depth
 image quality
 implantation
K10plus-PPN:1738566706
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68660362   QR-Code
zum Seitenanfang