Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Levin, Ingeborg [VerfasserIn]   i
 Karstens, Ute [VerfasserIn]   i
 Eritt, Markus [VerfasserIn]   i
 Maier, Fabian [VerfasserIn]   i
 Arnold, Sabrina [VerfasserIn]   i
 Rzesanke, Daniel [VerfasserIn]   i
 Hammer, Samuel [VerfasserIn]   i
 Ramonet, Michel [VerfasserIn]   i
 Vítková, Gabriela [VerfasserIn]   i
 Conil, Sebastien [VerfasserIn]   i
 Heliasz, Michal [VerfasserIn]   i
 Kubistin, Dagmar [VerfasserIn]   i
 Lindauer, Matthias [VerfasserIn]   i
Titel:A dedicated flask sampling strategy developed for Integrated Carbon Observation System (ICOS) stations based on CO2 and CO measurements and Stochastic Time-Inverted Lagrangian Transport (STILT) footprint modelling
Verf.angabe:Ingeborg Levin, Ute Karstens, Markus Eritt, Fabian Maier, Sabrina Arnold, Daniel Rzesanke, Samuel Hammer, Michel Ramonet, Gabriela Vítková, Sebastien Conil, Michal Heliasz, Dagmar Kubistin, and Matthias Lindauer
E-Jahr:2020
Jahr:29 September 2020
Umfang:20 S.
Fussnoten:Gesehen am 12.11.2020
Titel Quelle:Enthalten in: Atmospheric chemistry and physics
Ort Quelle:Katlenburg-Lindau : EGU, 2001
Jahr Quelle:2020
Band/Heft Quelle:20(2020), 18, Seite 11161-11180
ISSN Quelle:1680-7324
Abstract:Abstract. In situ CO2 and CO measurements from five Integrated Carbon Observation System (ICOS) atmosphere stations have been analysed together with footprint model runs from the regional Stochastic Time-Inverted Lagrangian Transport (STILT) model to develop a dedicated strategy for flask sampling with an automated sampler. Flask sampling in ICOS has three different purposes, namely (1) to provide an independent quality control for in situ observations, (2) to provide representative information on atmospheric components currently not monitored in situ at the stations, and (3) to collect samples for 14CO2 analysis that are significantly influenced by fossil fuel CO2 (ffCO2) emission areas. Based on the existing data and experimental results obtained at the Heidelberg pilot station with a prototype flask sampler, we suggest that single flask samples are collected regularly every third day around noon or in the afternoon from the highest level of a tower station. Air samples shall be collected over 1&thinsp;h, with equal temporal weighting, to obtain a true hourly mean. At all stations studied, more than 50&thinsp;% of flasks collected around midday will likely be sampled during low ambient variability (<0.5 parts per million (ppm) standard deviation of 1 min values). Based on a first application at the Hohenpeißenberg ICOS site, such flask data are principally suitable for detecting CO2 concentration biases larger than 0.1 ppm with a 1σ confidence level between flask and in situ observations from only five flask comparisons. In order to have a maximum chance to also sample ffCO2 emission areas, additional flasks are collected on all other days in the afternoon. To check if the ffCO2 component will indeed be large in these samples, we use the continuous in situ CO observations. The CO deviation from an estimated background value is determined the day after each flask sampling, and depending on this offset, an automated decision is made as to whether a flask shall be retained for 14CO2 analysis. It turned out that, based on existing data, ffCO2 events of more than 4-5 ppm that would allow ffCO2 estimates with an uncertainty below 30% were very rare at all stations studied, particularly in summer (only zero to five events per month from May to August). During the other seasons, events could be collected more frequently. The strategy developed in this project is currently being implemented at the ICOS stations.
DOI:doi:10.5194/acp-20-11161-2020
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext: https://doi.org/https://doi.org/10.5194/acp-20-11161-2020
 Volltext: https://acp.copernicus.org/articles/20/11161/2020/
 DOI: https://doi.org/10.5194/acp-20-11161-2020
Datenträger:Online-Ressource
Sprache:eng
K10plus-PPN:173857024X
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68660376   QR-Code
zum Seitenanfang