Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Mlynarska-Bujny, Anna [VerfasserIn]   i
 Bickelhaupt, Sebastian [VerfasserIn]   i
 Laun, Frederik B. [VerfasserIn]   i
 König, Franziska [VerfasserIn]   i
 Lederer, Wolfgang [VerfasserIn]   i
 Daniel, Heidi [VerfasserIn]   i
 Ladd, Mark E. [VerfasserIn]   i
 Schlemmer, Heinz-Peter [VerfasserIn]   i
 Delorme, Stefan [VerfasserIn]   i
 Kuder, Tristan Anselm [VerfasserIn]   i
Titel:Influence of residual fat signal on diffusion kurtosis MRI of suspicious mammography findings
Verf.angabe:Anna Mlynarska-Bujny, Sebastian Bickelhaupt, Frederik Bernd Laun, Franziska König, Wolfgang Lederer, Heidi Daniel, Mark Edward Ladd, Heinz-Peter Schlemmer, Stefan Delorme & Tristan Anselm Kuder
E-Jahr:2020
Jahr:06 August 2020
Umfang:12 S.
Fussnoten:Gesehen am 17.11.2020
Titel Quelle:Enthalten in: Scientific reports
Ort Quelle:[London] : Macmillan Publishers Limited, part of Springer Nature, 2011
Jahr Quelle:2020
Band/Heft Quelle:10(2020), Artikel-ID 13286, Seite 1-12
ISSN Quelle:2045-2322
Abstract:Recent studies showed the potential of diffusion kurtosis imaging (DKI) as a tool for improved classification of suspicious breast lesions. However, in diffusion-weighted imaging of the female breast, sufficient fat suppression is one of the main factors determining the success. In this study, the data of 198 patients examined in two study centres was analysed using standard diffusion and kurtosis evaluation methods and three DKI fitting approaches accounting phenomenologically for fat-related signal contamination of the lesions. Receiver operating characteristic curve analysis showed the highest area under the curve (AUC) for the method including fat correction terms (AUC = 0.85, p < 0.015) in comparison to the values obtained with the standard diffusion (AUC = 0.77) and kurtosis approach (AUC = 0.79). Comparing the two study centres, the AUC value improved from 0.77 to 0.86 (p = 0.036) using a fat correction term for the first centre, while no significant difference with no adverse effects was observed for the second centre (AUC 0.89 vs. 0.90, p = 0.95). Contamination of the signal in breast lesions with unsuppressed fat causing a reduction of diagnostic performance of diffusion kurtosis imaging may potentially be counteracted by proposed adapted evaluation methods.
DOI:doi:10.1038/s41598-020-70154-3
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext ; Verlag: https://doi.org/10.1038/s41598-020-70154-3
 Volltext: https://www.nature.com/articles/s41598-020-70154-3
 DOI: https://doi.org/10.1038/s41598-020-70154-3
Datenträger:Online-Ressource
Sprache:eng
K10plus-PPN:1738906795
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68661741   QR-Code
zum Seitenanfang