![]() | ![]() |
![]() | |
Verfasst von: | Aubry, N. [VerfasserIn] ![]() |
Gil, Alejandro [VerfasserIn] ![]() | |
Harion, Tobias [VerfasserIn] ![]() | |
Schultz-Coulon, Hans-Christian [VerfasserIn] ![]() | |
Schwaiger, M. [VerfasserIn] ![]() | |
Shen, Wei [VerfasserIn] ![]() | |
Silenzi, A. [VerfasserIn] ![]() | |
Silva, J. C. [VerfasserIn] ![]() | |
Silva, R. [VerfasserIn] ![]() | |
Schweiger, I. Somlai [VerfasserIn] ![]() | |
Stamen, Rainer [VerfasserIn] ![]() | |
Traub, J. [VerfasserIn] ![]() | |
Varela, J. [VerfasserIn] ![]() | |
Veckalns, V. [VerfasserIn] ![]() | |
Vidal, V. [VerfasserIn] ![]() | |
Vishwas, J. [VerfasserIn] ![]() | |
Wendler, T. [VerfasserIn] ![]() | |
Xu, C. [VerfasserIn] ![]() | |
Ziegler, S. [VerfasserIn] ![]() | |
Zvolsky, M. [VerfasserIn] ![]() | |
Titel: | EndoTOFPET-US |
Titelzusatz: | a novel multimodal tool for endoscopy and positron emission tomography |
Verf.angabe: | N. Aubry, E. Auffray, F.B. Mimoun, N. Brillouet, R. Bugalho, E. Charbon, O. Charles, D. Cortinovis, P. Courday, A. Cserkaszky, C. Damon, K. Doroud, J.-M. Fischer, G. Fornaro, J.-M. Fourmigue, B. Frisch, B. Fürst, J. Gardiazabal, K. Gadow, E. Garutti, C. Gaston, A. Gil-Ortiz, E. Guedj, T. Harion, P. Jarron, J. Kabadanian, T. Lasser, R. Laugier, P. Lecoq, D. Lombardo, S. Mandai, E. Mas, T. Meyer, O. Mundler, N. Navab, C. Ortigão, M. Paganoni, D. Perrodin, M. Pizzichemi, J.O. Prior, T. Reichl, M. Reinecke, M. Rolo, H.-C. Schultz-Coulon, M. Schwaiger, W. Shen, A. Silenzi, J.C. Silva, R. Silva, I. Somlai Schweiger, R. Stamen, J. Traub, J. Varela, V. Veckalns, V. Vidal, J. Vishwas, T. Wendler, C. Xu, S. Ziegler and M. Zvolsky |
E-Jahr: | 2013 |
Jahr: | 2 April 2013 |
Fussnoten: | Gesehen am 27.11.2020 ; 14th International workshop on radiation imaging detectors,1–5 July 2012, Figueira Dafoz, Portugal |
Titel Quelle: | Enthalten in: Journal of Instrumentation |
Ort Quelle: | London : Inst. of Physics, 2006 |
Jahr Quelle: | 2013 |
Band/Heft Quelle: | 8(2013,4) Artikel-Nummer C04002, 6 Seiten |
ISSN Quelle: | 1748-0221 |
Abstract: | The EndoTOFPET-US project aims to develop a multimodal detector to foster the development of new biomarkers for prostate and pancreatic tumors. The detector will consist of two main components: an external plate, and a PET extension to an endoscopic ultrasound probe. The external plate is an array of LYSO crystals read out by silicon photomultipliers (SiPM) coupled to an Application Specific Integrated Circuit (ASIC). The internal probe will be an highly integrated and miniaturized detector made of LYSO crystals read out by a fully digital SiPM featuring photosensor elements and digital readout in the same chip. The position and orientation of the two detectors will be tracked with respect to the patient to allow the fusion of the metabolic image from the PET and the anatomic image from the ultrasound probe in the time frame of the medical procedure. The fused information can guide further interventions of the organ, such as biopsy or in vivo confocal microscopy. |
DOI: | doi:10.1088/1748-0221/8/04/C04002 |
URL: | Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt. Volltext: https://doi.org/10.1088/1748-0221/8/04/C04002 |
DOI: https://doi.org/10.1088/1748-0221/8/04/C04002 | |
Datenträger: | Online-Ressource |
Sprache: | eng |
K10plus-PPN: | 1741321026 |
Verknüpfungen: | → Zeitschrift |