Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Huixia, Yang [VerfasserIn]   i
 Zhang, Xinmiao [VerfasserIn]   i
 Hao, Zengping [VerfasserIn]   i
Titel:The diagnostic accuracy of a real-time optoelectronic device in cervical cancer screening
Titelzusatz:A PRISMA-compliant systematic review and meta-analysis
Verf.angabe:Huixia Yang, Xinmiao Zhang, Zengping Hao
E-Jahr:2018
Jahr:July 2018
Umfang:7 S.
Fussnoten:Gesehen am 09.12.2020
Titel Quelle:Enthalten in: Medicine
Ort Quelle:Baltimore, Md. : Lippincott Williams & Wilkins, 1922
Jahr Quelle:2018
Band/Heft Quelle:97(2018,29) Artikel-Nummer e11439, 7 Seiten
ISSN Quelle:1536-5964
Abstract:Background: This study aimed to assess the diagnostic accuracy of a real-time optoelectronic device (TruScreen) for uterine cervical cancer screening. Methods: On the basis of Preferred Reporting Items for Systematic Reviews and Meta-analyses (the PRISMA statement) we performed this systematic review and meta-analysis. We searched PubMed, EMBASE, the Cochrane Library, CNKI, CBM, and WanFang Data using medical subject headings (MeSH) and text words. Title/abstract screening, full text check, data extraction, and methodological quality assessment (with the QUADAS-2 tool) were performed by 2 reviewers independently. The pooled sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR), the summary receiver operator characteristic curve, and the area under the curve (AUC) were analyzed with Meta-DiSc software. Statistical heterogeneity was evaluated by Cochran's Q test and I2, meta-regression was conducted based on patient type, and the possibility of publication bias was evaluated using Deeks funnel plot in Stata software. Results: Of 293 publications, nine met our inclusion criteria. These studies included a total of 2730 patients and 567 cervical intraepithelial neoplasias. The pooled test characteristics for the TruScreen were as follows: sensitivity 76% (95% CI, 73-80%), specificity 69% (95% CI, 67%-71%), PLR 2.30 (95% CI, 1.59-3.33), and NLR 0.34 (95% CI, 0.23-0.51). The corresponding pooled DOR was 7.03 (95% CI, 3.40-14.55). The AUC was 0.7859 (Q* = 0.7236). Conclusion: The diagnostic accuracy of the TruScreen device is moderately good. The study findings are based on Chinese studies only and could not be generalized to other populations.
DOI:doi:10.1097/MD.0000000000011439
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext: https://doi.org/10.1097/MD.0000000000011439
 Volltext: https://journals.lww.com/md-journal/Fulltext/2018/07200/The_diagnostic_accuracy_of_a_real_time.24.aspx
 DOI: https://doi.org/10.1097/MD.0000000000011439
Datenträger:Online-Ressource
Sprache:eng
K10plus-PPN:1742358802
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68670899   QR-Code
zum Seitenanfang