| Online-Ressource |
Verfasst von: | Großgasteiger, Manuel [VerfasserIn]  |
| Hien, Maximilian [VerfasserIn]  |
| Graser, Bastian [VerfasserIn]  |
| Rauch, Helmut [VerfasserIn]  |
| Gondan, Matthias [VerfasserIn]  |
| Motsch, Johann [VerfasserIn]  |
| Rosendal, Christian [VerfasserIn]  |
Titel: | Assessment of left ventricular size and function during cardiac surgery |
Titelzusatz: | an intraoperative evaluation of six two-dimensional echocardiographic methods with real time three-dimensional echocardiography as a reference |
Verf.angabe: | Manuel Grossgasteiger, Cand. Med., Maximilian D. Hien, M.D., Bastian Graser, M.Sc., Helmut Rauch, M.D., Matthias Gondan, Ph.D., Johann Motsch, M.D. and Christian Rosendal, M.D |
E-Jahr: | 2013 |
Jahr: | 14 February 2013 |
Umfang: | 10 S. |
Fussnoten: | Gesehen am 28.01.2021 |
Titel Quelle: | Enthalten in: Echocardiography |
Ort Quelle: | Armonk, NY : Futura, 1984 |
Jahr Quelle: | 2013 |
Band/Heft Quelle: | 30(2013), 6, Seite 672-681 |
ISSN Quelle: | 1540-8175 |
Abstract: | Transesophageal echocardiography is recommended to monitor left ventricular (LV) size and function in various operations. Generally, two-dimensional (2D) methods are applied intraoperatively. The aim of this study was to compare the accuracy and feasibility of 6 commonly used 2D methods to assess LV function during surgery. LV function in 120 consecutive patients was evaluated. Real time three-dimensional transesophageal echocardiograpy (3DTEE) served as reference. End-diastolic and end-systolic volumes and ejection fraction (EF) were analyzed with Simpson's method of discs (monoplane [MP] and biplane [BP]), eyeball method, Teichholz' method, and speckle tracking (ST) methods. Furthermore, fractional area change (FAC) and peak systolic pressure rise (dP/dt) were determined. Each 2D method was evaluated regarding correlation and agreement with 3DE, intra- and interobserver variability and the time required for evaluation. Simpson BP showed the strongest correlation and best agreement with 3DE for EF (limits of agreement 3.7 ± 11.6%) and volumes. Simpson MP showed similar agreement with 3DE compared to ST (2.8 ± 14.5% vs. 2.0 ± 15.3% and 3.8 ± 14.4% vs. 1.9 ± 15.6%, respectively). Both the eyeball method and Teichholz' method showed wide limits of agreement (−1.5 ± 18.2% and 5.2 ± 22.1%, respectively). DP/dt did not correlate with 3DE. FAC and ST FAC showed similar agreement. Application of 3DE (429 ± 108 seconds) took the longest time, and the eyeball method took the shortest time (8 ± 5 seconds) for analysis. Simpson BP is the most accurate intraoperative 2D method to evaluate LV function, followed by long-axis MP evaluations. Short-axis views were less accurate but may be suited for monitoring. We do not recommend using dP/dt. |
DOI: | doi:10.1111/echo.12116 |
URL: | Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.
Volltext: https://doi.org/https://doi.org/10.1111/echo.12116 |
| Volltext: https://onlinelibrary.wiley.com/doi/abs/10.1111/echo.12116 |
| DOI: https://doi.org/10.1111/echo.12116 |
Datenträger: | Online-Ressource |
Sprache: | eng |
Sach-SW: | intraoperative three-dimensional transesophageal echocardiography |
| peak systolic pressure rise |
| prospective observational study |
| Simpson's method of discs |
| speckle tracking |
| Teichholz' method |
K10plus-PPN: | 1745920676 |
Verknüpfungen: | → Zeitschrift |
Assessment of left ventricular size and function during cardiac surgery / Großgasteiger, Manuel [VerfasserIn]; 14 February 2013 (Online-Ressource)