Verfasst von:Eickholz, Peter [VerfasserIn]   i
 Grotkamp, Frank-Ludger [VerfasserIn]   i
 Staehle, Hans Jörg [VerfasserIn]   i
 Steveling, Helmut [VerfasserIn]   i
 Mühling, Joachim [VerfasserIn]   i
Titel:Reproducibility of peri-implant probing using a force-controlled probe
Verf.angabe:Peter Eickholz, Frank L. Grotkamp, Hans J. Staehle, Helmut Steveling, Joachim Mühling
Jahr:2001
Umfang:6 S.
Teil:volume:12
 year:2001
 number:2
 pages:153-158
 extent:6
Fussnoten:First published: 19 January 2002 ; Elektronische Reproduktion der Druck-Ausgabe ; Gesehen am 12.02.2021
Titel Quelle:Enthalten in: Clinical oral implants research
Ort Quelle:Oxford : Wiley-Blackwell, 1990
Jahr Quelle:2001
Band/Heft Quelle:12(2001), 2, Seite 153-158
ISSN Quelle:1600-0501
Abstract:The aim of the present study was to evaluate the reproducibility of probing depth (PD) and vertical attachment level (PAL-V) measurements at endosseous implants. Twenty partially edentulous patients who had received 44 Frialit-2 and 30 Astra implants between 1994 and 1996 were examined. At all teeth and implants, clinical parameters (GI, PlI, PD, PAL-V) were measured at 6 sites using the flexible plastic version of the universal explorer TPS probe. At the implants and at teeth that were in similar locations compared to the implants, PD and PAL-V measurements were repeated. For each of the 20 probes that had been used for clinical examination of the 20 patients, the probing force was assessed using a precision balance. As a measure of intraexaminer reproducibility, the following standard deviations of single PD and PAL-V measurements were calculated: Frialit-2: 0.71/0.74 mm; Astra: 0.72/0.75 mm; tooth: 0.59/0.57 mm (PD/PAL-V). Stepwise multiple regression analysis revealed implant/tooth position and GI to influence PD and PAL-V measurement error (P<0.001). At anterior teeth, a lower variability was observed than at posterior teeth (P<0.001). PD and PAL-V measurement error were higher at implants than at teeth and influenced by patients. The respective models explained 13% and 17% of the variability of the dependent variable (PD/PAL-V), respectively. Intraexaminer variability of PD and PAL-V measurements at implants tended to be higher than at teeth. Multivariate analysis of variance revealed probe and probe holder to statistically significantly (P<0.001) influence probing force. However, the differences in probing force between the various probe heads were very small. They reached a maximum of 0.054 N between probe 3 and 14 and may be looked upon as clinically irrelevant.
DOI:doi:10.1034/j.1600-0501.2001.012002153.x
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext ; Verlag: https://doi.org/https://doi.org/10.1034/j.1600-0501.2001.012002153.x
 Volltext: https://onlinelibrary.wiley.com/doi/abs/10.1034/j.1600-0501.2001.012002153.x