Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Golatta, Michael [VerfasserIn]   i
 Schweitzer-Martin, Mirjam [VerfasserIn]   i
 Harcos, Aba [VerfasserIn]   i
 Schott, Sarah [VerfasserIn]   i
 Junkermann, Hans [VerfasserIn]   i
 Rauch, Geraldine [VerfasserIn]   i
 Sohn, Christof [VerfasserIn]   i
 Heil, Jörg [VerfasserIn]   i
Titel:Normal breast tissue stiffness measured by a new ultrasound technique
Titelzusatz:virtual touch tissue imaging quantification (VTIQ)
Verf.angabe:Michael Golatta, Mirjam Schweitzer-Martin, Aba Harcos, Sarah Schott, Hans Junkermann, Geraldine Rauch, Christof Sohn, Jörg Heil
E-Jahr:2013
Jahr:8 August 2013
Umfang:4 S.
Fussnoten:Gesehen am 17.02.2020
Titel Quelle:Enthalten in: European journal of radiology
Ort Quelle:Amsterdam [u.a.] : Elsevier Science, 1990
Jahr Quelle:2013
Band/Heft Quelle:82(2013), 11, Seite e676-e679
ISSN Quelle:1872-7727
Abstract:Objective - To evaluate normal breast tissue stiffness with virtual touch tissue imaging quantification (VTIQ) using prospectively collected data. - Materials and Methods - B-mode ultrasound and VTIQ were performed in 132 breasts in 97 women. Mean values of VTIQ for parenchyma and fatty tissue were compared between those measured in healthy breasts and in the surrounding of histologically proven benign and malignant breast lesions. Moreover we reviewed VTIQ values according to breast density measured by the American College of Radiology (ACR) categories. In addition we analyzed re-test reliability of VTIQ. - Results - In 132 breasts the mean VTIQ values in parenchyma were significantly higher than in fatty tissue (3.23m/s±0.74 versus 2.5m/s±0.61; p<0.0001). In healthy breasts as well as in the surrounding of a benign or malignant lesions the VTIQ values of parenchyma were similar (p=0.12). In fatty tissue, small differences between mean VTIQ values of 2.25m/s±0.51, 2.52m/s±0.48 and 2.65m/s±0.71 (p=0.01) in the respective groups were observed. The comparison of mean VTIQ values of parenchyma and fatty tissue in more and less dense breasts (ACR 1+2 versus ACR 3+4 breasts) also yielded no statistically significant difference. The re-test reliability of VTIQ assessed with three independent measurements was moderate (interclass-correlation of 0.52 (p<0.0001)). - Conclusion - VTIQ is a reliable method for measuring the stiffness of breast tissue. We propose standard values for healthy parenchyma and fatty tissues independent of the surrounding tissue or the ACR category.
DOI:doi:10.1016/j.ejrad.2013.06.029
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext: https://doi.org/10.1016/j.ejrad.2013.06.029
 Volltext: https://www.sciencedirect.com/science/article/pii/S0720048X13003574
 DOI: https://doi.org/10.1016/j.ejrad.2013.06.029
Datenträger:Online-Ressource
Sprache:eng
Sach-SW:Breast ultrasound
 Shear wave elastography
 Standard value
 Virtual touch tissue imaging quantification (VTIQ)
K10plus-PPN:1748482645
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68700401   QR-Code
zum Seitenanfang