Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Auffarth, Gerd U. [VerfasserIn]   i
 Gerl, Matthias [VerfasserIn]   i
 Tsai, Linda [VerfasserIn]   i
 Janakiraman, D. Priya [VerfasserIn]   i
 Jackson, Beth [VerfasserIn]   i
 Alarcon, Aixa [VerfasserIn]   i
 Dick, H. Burkhard [VerfasserIn]   i
Titel:Clinical evaluation of a new monofocal IOL with enhanced intermediate function in patients with cataract
Verf.angabe:Gerd U. Auffarth, MD, PhD, FEBO, Matthias Gerl, MD, Linda Tsai, MPH, D. Priya Janakiraman, OD, FAAO, Beth Jackson, PhD, Aixa Alarcon, PhD, H. Burkhard Dick, MD, PhD, FEBOS-CR, Quantum Study Group
E-Jahr:2021
Jahr:February 2021
Umfang:8 S.
Fussnoten:Gesehen am 08.04.2021
Titel Quelle:Enthalten in: Journal of cataract and refractive surgery
Ort Quelle:Fairfax, Va. : Soc., 1986
Jahr Quelle:2021
Band/Heft Quelle:47(2021), 2, Seite 184-191
ISSN Quelle:1873-4502
Abstract:Purpose: - To evaluate the effectiveness and safety of 2 enhanced monofocal intraocular lenses (IOLs). The TECNIS Eyhance IOL (Model ICB00) was compared with a standard monofocal IOL (TECNIS Monofocal, Model ZCB00). - Setting: - European multicenter study. - Design: - Prospective, bilateral, randomized, comparative/evaluator-masked, controlled study. - Methods: - Adult subjects scheduled to undergo bilateral, primary phacoemulsification cataract extraction and posterior IOL implantation were randomized to receive the enhanced monofocal ICB00 IOL or the monofocal ZCB00 IOL in both eyes. Monocular endpoints at 6 months included distance-corrected intermediate visual acuity (DCIVA), photopic corrected distance visual acuity, and uncorrected intermediate visual acuity (UIVA). Binocular visual acuities, monocular corrected distance contrast sensitivity (first eyes), patient-reported outcomes, and safety were assessed at 6 months. - Results: - Overall, 139 patients were bilaterally implanted with the enhanced monofocal IOL (n = 67) or standard monofocal IOL (n = 72) and available for the 6-month visit. The enhanced monofocal IOL significantly improved mean monocular and binocular DCIVA and UIVA by at least 1-line logarithm of the minimum angle of resolution vs the standard monofocal IOL (all P ≤ .0001). Distance vision for the enhanced monofocal IOL was 20/20 or better and comparable with that of the standard monofocal lens at 6 months. Contrast sensitivity, photic phenomena outcomes, and rates of adverse events were similar between the 2 groups. - Conclusions: - In patients undergoing cataract surgery, TECNIS Eyhance IOL Model ICB00 provided enhanced intermediate vision and similar distance performance and photic phenomena compared with a standard monofocal IOL, along with improved functional performance in daily life.
DOI:doi:10.1097/j.jcrs.0000000000000399
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext: https://doi.org/10.1097/j.jcrs.0000000000000399
 Volltext: https://journals.lww.com/jcrs/Fulltext/2021/02000/Clinical_evaluation_of_a_new_monofocal_IOL_with.8.aspx
 DOI: https://doi.org/10.1097/j.jcrs.0000000000000399
Datenträger:Online-Ressource
Sprache:eng
K10plus-PPN:1753225981
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68720657   QR-Code
zum Seitenanfang