Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Chen, Wenjing [VerfasserIn]   i
 Gemmel, Alexander [VerfasserIn]   i
 Rietzel, Eike [VerfasserIn]   i
Titel:A patient-specific planning target volume used in 'plan of the day' adaptation for interfractional motion mitigation
Verf.angabe:Wenjing Chen, Alexander Gemmel and Eike Rietzel
E-Jahr:2013
Jahr:20 April 2013
Umfang:9 S.
Teil:volume:54 Suppl 1
 year:2013
 pages:i82-90
 extent:9
Fussnoten:Gesehen am 09.04.2021
Titel Quelle:Enthalten in: Journal of radiation research
Ort Quelle:[Oxford] : Oxford University Press, 1960
Jahr Quelle:2013
Band/Heft Quelle:54 Suppl 1(2013), Seite i82-90
ISSN Quelle:1349-9157
Abstract:We propose a patient-specific planning target volume (PTV) to deal with interfractional variations, and test its feasibility in a retrospective treatment-planning study. Instead of using one planning image only, multiple scans are taken on different days. The target and organs at risk (OARs) are delineated on each images. The proposed PTV is generated from a union of those target contours on the planning images, excluding voxels of the OARs, and is denoted the PTV 'GP-OAR' (global prostate-organs at risk). The study is performed using 'plan of the day' adaptive workflow, which selects a daily plan from a library of plans based on a similarity comparison between the daily scan and planning images. The daily plans optimized for GP-OAR volumes are compared with those optimized for PTVs generated from a single prostate contour (PTV SP). Four CT serials of prostate cancer patient datasets are included in the test, and in total 28 fractions are simulated. The results show that the daily chosen GP-OAR plans provide excellent target coverage, with V95 values of the prostate mostly > 95%. In addition, dose delivered to the OARs as calculated from applying daily chosen GP-OAR plans is slightly increased but comparable to that calculated from applying daily SP plans. In general, the PTV GP-OARs are able to cover possible target variations while keeping dose delivered to the OARs at a similar level to that of the PTV SPs.
DOI:doi:10.1093/jrr/rrt070
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

DOI: https://doi.org/10.1093/jrr/rrt070
Datenträger:Online-Ressource
Sprache:eng
Sach-SW:Algorithms
 Carbon
 Heavy Ion Radiotherapy
 Humans
 Ions
 Male
 Motion
 organ motion
 Organs at Risk
 particle therapy
 planning target volume
 prostate
 Prostatic Neoplasms
 Radiotherapy Dosage
 Radiotherapy Planning, Computer-Assisted
 Retrospective Studies
 Tomography, X-Ray Computed
 treatment planning
K10plus-PPN:1753569214
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68721786   QR-Code
zum Seitenanfang