Titel:Evaluation of the KLauS ASIC at low temperature
Verf.angabe:Wei Wang, Wei Shen, Zhenxiong Yuan, Konrad Briggl, Hans-Christian Schultz-Coulon, Erik Warttmann, Wenqi Yan, Guofu Cao, Zepeng Li, Ming Qi, Liangjian Wen
E-Jahr:2021
Jahr:4 February 2021
Umfang:9 S.
Fussnoten:Gesehen am 03.08.2021
Titel Quelle:Enthalten in: Nuclear instruments & methods in physics research / A
Ort Quelle:Amsterdam : North-Holland Publ. Co., 1984
Jahr Quelle:2021
Band/Heft Quelle:996(2021), Artikel-ID 165110, Seite 1-9
ISSN Quelle:1872-9576
Abstract:The Taishan Antineutrino Observatory (TAO) is proposed to first use a cold liquid scintillator detector (−50 °C) equipped with large-area silicon photomultipliers (SiPMs) (∼10 m2) to precisely measure the reactor antineutrino spectrum with a record energy resolution of ¡ 2% at 1 MeV. The KLauS ASIC shows excellent performance at room temperature and is a potential readout solution for TAO. In this work, we report evaluations of the fifth version of the KLauS ASIC (KLauS5) from room temperature to -50 °C with inputs of injected charge or SiPMs. Our results show that KLauS5 has good performance at the tested temperatures with no significant degradation of the charge noise, charge linearity, gain uniformity or recovery time. Meanwhile, we also observe that several key parameters degrade when the chip operates in cold conditions, including the dynamic range and power consumption. However, even with this degradation, a good signal-to-noise ratio and good resolution of a single photoelectron can still be achieved for the tested SiPM with a gain of greater than 1.5 × 106 and even an area of SiPM up to 1 cm2 in one channel, corresponding to an input capacitance of approximately 5 nF. Thus, we conclude that KLauS5 can fulfill the TAO requirements for precise charge measurement.
DOI:doi:10.1016/j.nima.2021.165110
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext: https://doi.org/10.1016/j.nima.2021.165110
 Volltext: https://www.sciencedirect.com/science/article/pii/S0168900221000942
 DOI: https://doi.org/10.1016/j.nima.2021.165110
Datenträger:Online-Ressource
Sprache:eng
Sach-SW:KLauS ASIC
 Reactor antineutrino spectrum
 SiPM
 TAO
K10plus-PPN:1756119074
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68729658   QR-Code
zum Seitenanfang