Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---

+ Andere Auflagen/Ausgaben
heiBIB
 Online-Ressource
Verfasst von:Hadaschik, Boris [VerfasserIn]   i
 Kuru, Timur Hasan [VerfasserIn]   i
 Tulea, Corina [VerfasserIn]   i
 Rieker, Philip [VerfasserIn]   i
 Popeneciu, Valentin [VerfasserIn]   i
 Simpfendörfer, Tobias [VerfasserIn]   i
 Huber, Johannes [VerfasserIn]   i
 Zogal, Pawel [VerfasserIn]   i
 Teber, Dogu [VerfasserIn]   i
 Pahernik, Sascha [VerfasserIn]   i
 Röthke, Matthias C. [VerfasserIn]   i
 Zamecnik, Patrik [VerfasserIn]   i
 Roth, Wilfried [VerfasserIn]   i
 Sakas, Georgios [VerfasserIn]   i
 Schlemmer, Heinz-Peter [VerfasserIn]   i
 Hohenfellner, Markus [VerfasserIn]   i
Titel:A novel stereotactic prostate biopsy system integrating pre-interventional magnetic resonance imaging and live ultrasound fusion
Verf.angabe:Boris A. Hadaschik, Timur H. Kuru, Corina Tulea, Philip Rieker, Ionel V. Popeneciu, Tobias Simpfendörfer, Johannes Huber, Pawel Zogal, Dogu Teber, Sascha Pahernik, Matthias Roethke, Patrik Zamecnik, Wilfried Roth, Georgios Sakas, Heinz-Peter Schlemmer and Markus Hohenfellner
Jahr:2011
Umfang:7 S.
Teil:volume:186
 year:2011
 number:6
 month:12
 pages:2214-2220
 extent:7
Fussnoten:Submitted for publication April 20, 2011 ; Gesehen am 15.07.2021
Titel Quelle:Enthalten in: The journal of urology
Ort Quelle:New York, NY [u.a.] : Elsevier, 1917
Jahr Quelle:2011
Band/Heft Quelle:186(2011), 6 vom: Dez., Seite 2214-2220
ISSN Quelle:1527-3792
Abstract:Purpose: We developed an effective way to precisely diagnose prostate cancer using a novel prostate biopsy system that integrates pre-interventional magnetic resonance imaging with peri-interventional ultrasound for perineal navigated prostate biopsy. Materials and Methods: A total of 106 men with findings suspicious for prostate cancer (median age 66 years, prostate specific antigen 8.0 ng/ml and prostate volume 47 ml) underwent multiparametric 3 Tesla magnetic resonance imaging. Suspicious lesions were marked and data were transferred to the novel biopsy system. Using a custom-made biplane transrectal ultrasound probe mounted on a stepper we gathered 3-dimensional ultrasound data and fused them with magnetic resonance imaging data. As a result, suspicious magnetic resonance imaging lesions were superimposed over the transrectal ultrasound data. Three-dimensional biopsy planning was done, including systematic biopsies. Perineal biopsies were taken under live ultrasound guidance and the precise site of each biopsy was documented in 3 dimensions. We evaluated feasibility, safety and cancer detection. Results: Prostate cancer was detected in 63 of 106 patients (59.4%). Magnetic resonance imaging findings correlated positively with histopathology in 71 of 103 patients (68.9%). In magnetic resonance imaging lesions marked as highly suspicious, the detection rate was 95.8% (23 of 24 cases). Lesion targeted cores had a significantly higher positivity rate than nontargeted cores. The procedural targeting error of the first 2,461 biopsy cores was 1.7 mm. Regarding adverse effects, 2 patients experienced urinary retention and 1 had a perineal hematoma. Urinary tract infections did not develop. Conclusions: Perineal stereotactic prostate biopsies guided by the combination of magnetic resonance imaging and ultrasound enable effective examination of suspicious magnetic resonance imaging lesions. Each biopsy core taken is documented accurately for its location in 3 dimensions, enabling magnetic resonance imaging validation and tailored treatment planning. The morbidity of the procedure was minimal.
DOI:doi:10.1016/j.juro.2011.07.102
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext ; Verlag: https://doi.org/10.1016/j.juro.2011.07.102
 Volltext: https://www.auajournals.org/doi/abs/10.1016/j.juro.2011.07.102
 DOI: https://doi.org/10.1016/j.juro.2011.07.102
Datenträger:Online-Ressource
Sprache:eng
Bibliogr. Hinweis:Erscheint auch als : Druck-Ausgabe: Hadaschik, Boris, 1974 - : A novel stereotactic prostate biopsy system integrating pre-interventional magnetic resonance imaging and live ultrasound fusion. - 2011
Sach-SW:biopsy
 magnetic resonance imaging
 prostate
 prostatic neoplasms
 ultrasonography
K10plus-PPN:176297214X
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68760401   QR-Code
zum Seitenanfang