Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Schramm, Christoph [VerfasserIn]   i
 Huber, Anja Carmen [VerfasserIn]   i
 Plaschke, Konstanze [VerfasserIn]   i
Titel:The accuracy and responsiveness of continuous noninvasive arterial pressure during rapid ventricular pacing for transcatheter aortic valve replacement
Verf.angabe:Christoph Schramm, Anja Huber, and Konstanze Plaschke
E-Jahr:2013
Jahr:May 17, 2013
Umfang:7 S.
Teil:volume:117
 year:2013
 number:1
 pages:76-82
 extent:7
Fussnoten:Gesehen am 19.07.2021
Titel Quelle:Enthalten in: Anesthesia & analgesia
Ort Quelle:Baltimore, Md. : Williams & Wilkins, 1957
Jahr Quelle:2013
Band/Heft Quelle:117(2013), 1, Seite 76-82
ISSN Quelle:1526-7598
Abstract:Background: The accuracy of measurement of the continuous noninvasive arterial blood pressure (CNAP) technique is unknown during sudden cardiocirculatory arrest. - Methods: In 33 patients undergoing elective transfemoral aortic valve implantation procedures under analgesic sedation, invasive arterial blood pressure (IAP) was compared with a CNAP device during episodes of severe hypotension (functional cardiocirculatory arrests by rapid pacing) and the remaining time without severe hypotension. Systolic, diastolic, and mean pairs of blood pressure measurements were extracted for both groups and were analyzed by Bland-Altman plots. The responsiveness of the CNAP technique was assessed in the various phases of severe hypotension concerning time and amplitude of changes. - Results: Overall CNAP accuracy (bias), calculated by subtracting IAP from CNAP, was −6.3 ± 18.9, 7.4 ± 10.5, and 4.0 ± 11.3 mm Hg (mean ± SD, systolic, diastolic, and mean). Bias increased during episodes of severe hypotension to 11.8 ± 14.5, 13.8 ± 12.4, and 12.9 ± 12.4 mm Hg. The percentage of agreements (95% confidence interval) between the blood pressure pairs with a difference ≤15 mm Hg was 58.5% (57.9-58.6), 75.8% (75.5-76.0), 82.2% (81.9-82.4; systolic, diastolic, mean) for all data and 56.4% (54.2-58.9; P = 0.71), 53.2%* (51.1-56.0), and 57.4%* (56.3-59.1; *P < 0.001) during rapid pacing. The responsiveness of mean CNAP and mean IAP did not differ significantly during the various phases of rapid pacing. - Conclusions: The stand-alone CNAP monitor (model 500at, software V3.5) accurately and rapidly measures the changes of blood pressure that occur during sudden development of cardiocirculatory arrest and recovery to baseline blood pressures. CNAP monitors the duration of the arrest.
DOI:doi:10.1213/ANE.0b013e3182910df5
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext ; Verlag: https://doi.org/10.1213/ANE.0b013e3182910df5
 Volltext: https://journals.lww.com/anesthesia-analgesia/Fulltext/2013/07000/The_Accuracy_and_Responsiveness_of_Continuous.13.aspx
 DOI: https://doi.org/10.1213/ANE.0b013e3182910df5
Datenträger:Online-Ressource
Sprache:eng
K10plus-PPN:1763152006
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68761071   QR-Code
zum Seitenanfang