| Online-Ressource |
Verfasst von: | Roser, Christoph [VerfasserIn]  |
| Hodecker, Lutz [VerfasserIn]  |
| Köbel, Chris [VerfasserIn]  |
| Lux, Christopher J. [VerfasserIn]  |
| Ruckes, Dorothee [VerfasserIn]  |
| Rues, Stefan [VerfasserIn]  |
| Zenthöfer, Andreas [VerfasserIn]  |
Titel: | Mechanical properties of CAD/CAM-fabricated in comparison to conventionally fabricated functional regulator 3 appliances |
Verf.angabe: | Christoph Roser, Lutz D. Hodecker, Chris Koebel, Christopher J. Lux, Dorothee Ruckes, Stefan Rues and Andreas Zenthöfer |
E-Jahr: | 2021 |
Jahr: | 19 July 2021 |
Umfang: | 10 S. |
Fussnoten: | Gesehen am 24.09.2021 |
Titel Quelle: | Enthalten in: Scientific reports |
Ort Quelle: | [London] : Macmillan Publishers Limited, part of Springer Nature, 2011 |
Jahr Quelle: | 2021 |
Band/Heft Quelle: | 11(2021), Artikel-ID 14719, Seite 1-10 |
ISSN Quelle: | 2045-2322 |
Abstract: | Manufacturing of Fränkel's functional regulator 3 (FR3) is complicated and requires extensive knowledge from the dental technician. To determine whether FR3s produced by CAD/CAM techniques (CAD-FR3) meet similar mechanical properties like conventional FR3s (Con-FR3), for each of 10 patient cases, three CAD-FR3 designs (palatal connector cross-section 3 × 3 mm, 4 × 1 mm or 5 × 2 mm) and one Con-FR3 were subjected to cyclic loading and subsequent fracture testing in a universal testing device. Transversal load capacity (Fmax(FR3)) and stiffness were compared among the different CAD-FR3 designs and Con-FR3s using Friedman and Wilcoxon tests with a significance level of α = 0.05. All CAD-FR3 designs had significantly higher mean Fmax(FR3) (p ≤ 0.007) and stiffness (p ≤ 0.005) than the Con-FR3s. The CAD-FR33×3 had the highest mean Fmax(FR3) (98.2 ± 26.2 N) and stiffness (37.1 ± 15.5 N/mm), closely followed by the CAD-FR35×2 (Fmax(FR3): 90.3 ± 24.7 N; stiffness: 30.0 ± 12.3 N/mm). Among the CAD appliances, CAD-FR34×1 had the lowest values (p ≤ 0.007 for all pairwise tests) with Fmax(FR3) of 45.8 ± 17.9 N and stiffness of 12.5 ± 7.3 N/mm. CAD-FR3s have superior mechanical properties in comparison to Con-FR3s if certain design parameters are followed. Further clinical investigations have to examine if they can serve as an alternative in practice. |
DOI: | doi:10.1038/s41598-021-94237-x |
URL: | kostenfrei: Volltext: https://doi.org/10.1038/s41598-021-94237-x |
| kostenfrei: Volltext: https://www.nature.com/articles/s41598-021-94237-x |
| DOI: https://doi.org/10.1038/s41598-021-94237-x |
Datenträger: | Online-Ressource |
Sprache: | eng |
K10plus-PPN: | 1771774789 |
Verknüpfungen: | → Zeitschrift |
|
|
| |
Lokale URL UB: | Zum Volltext |
Mechanical properties of CAD/CAM-fabricated in comparison to conventionally fabricated functional regulator 3 appliances / Roser, Christoph [VerfasserIn]; 19 July 2021 (Online-Ressource)