Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Chen, Xueping [VerfasserIn]   i
 Cheng, Shuk Han [VerfasserIn]   i
 Kinoshita, Masato [VerfasserIn]   i
 de Witte, Peter A. [VerfasserIn]   i
 Liu, Jianjun [VerfasserIn]   i
 Hinton, David [VerfasserIn]   i
 Braunbeck, Thomas [VerfasserIn]   i
 Cotgreave, Ian [VerfasserIn]   i
 Schlenk, Daniel [VerfasserIn]   i
 Gong, Zhiyuan [VerfasserIn]   i
 El-Nezami, Hani [VerfasserIn]   i
 Ho, Kin Chung [VerfasserIn]   i
 Chan, Kwok Fai [VerfasserIn]   i
 Xu, Shisan [VerfasserIn]   i
 Yiu, Pui Ying [VerfasserIn]   i
 Zhang, Huan [VerfasserIn]   i
 Wu, Desheng [VerfasserIn]   i
 Chan, Yu Suen [VerfasserIn]   i
 Ny, Annelii [VerfasserIn]   i
 Maes, Jan [VerfasserIn]   i
Titel:Pre-validation of choriogenin H transgenic medaka eleutheroembryos as a quantitative estrogenic activity test method
Verf.angabe:Xueping Chen, Shuk Han Cheng, Masato Kinoshita, Peter A. de Witte, Jianjun Liu, David Hinton, Thomas Braunbeck, Ian Cotgreave, Daniel Schlenk, Zhiyuan Gong, Hani El-Nezami, Kin Chung Ho, Kwok Fai Chan, Shisan Xu, Pui Ying Yiu, Huan Zhang, Desheng Wu, Yu Suen Chan, Annelii Ny, Jan Maes
E-Jahr:2021
Jahr:21 July 2021
Umfang:8 S.
Teil:volume:629
 year:2021
 month:07
 elocationid:114311
 pages:1-8
 extent:8
Fussnoten:Gesehen am 24.09.2021
Titel Quelle:Enthalten in: Analytical biochemistry
Ort Quelle:San Diego, Calif. : Elsevier, 1960
Jahr Quelle:2021
Band/Heft Quelle:629(2021) vom: Juli, Artikel-ID 114311, Seite 1-8
ISSN Quelle:1096-0309
Abstract:The choriogenin H - EGFP transgenic medaka (Oryzias melastigma) has been used to test estrogenic substances and quantify estrogenic activity into 17 beta-estradiol (E2) equivalency (EEQ). The method uses 8 eleutheroembryos in 2 ml solution per well and 3 wells per treatment in 24-well plates at 26 +/- 1 degrees C for 24 +/- 2 h, with subsequent measurements of induced GFP signal intensity. EEQ measurements are calculated using a E2 probit regression model with a coefficient of determination (R2) 0.90. The selectivity was confirmed evaluating 27 known estrogenic and 5 known non-estrogenic compounds. Limit of quantitation (LOQ), recovery rate and bias were calculated to be 1 ng/ml EEQ, 104% and 4% respectively. Robustness analysis revealed exposure temperature is a sensitive parameter that should be kept at 26 +/- 1 degrees C. The repeatability of intra- and inter-laboratories achieved CV < 30% for most tested food and cosmetics samples. The lot-lot stability was confirmed by the stable EEQ qualitative control (QC, 1 ng/mL E2) and calibration curve results. The stability of standard reagents, samples and sample extracts was also investigated. These data demonstrated this method to be an accurate indicator of estrogenic activity for both chemicals and extracts.
DOI:doi:10.1016/j.ab.2021.114311
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext ; Verlag: https://doi.org/10.1016/j.ab.2021.114311
 Volltext: https://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcAuth=DOISource&SrcApp=WOS&KeyAID=10.1016%2Fj.ab.20 ...
 DOI: https://doi.org/10.1016/j.ab.2021.114311
Datenträger:Online-Ressource
Sprache:eng
Sach-SW:Bioanalytical method
 bone loss
 chemicals
 EEQ test
 estradiol
 Estrogen equivalency
 Estrogenic activity
 in-vitro
 isoflavones
 quantification
 rats
 receptor transcriptional activation
 Semi-quantitative
 toxicity
 Transgenic medaka
K10plus-PPN:1771787546
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68783265   QR-Code
zum Seitenanfang