Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Łabuz, Grzegorz [VerfasserIn]   i
 Yildirim, Timur Mert [VerfasserIn]   i
 Khoramnia, Ramin [VerfasserIn]   i
 Son, Hyeck Soo [VerfasserIn]   i
 Auffarth, Gerd U. [VerfasserIn]   i
Titel:Optical function of intraocular lenses in different opacification patterns
Titelzusatz:metrology analysis of 67 explants
Verf.angabe:Grzegorz Labuz, Timur M. Yildirim, Ramin Khoramnia, Hyeck-Soo Son, Gerd U. Auffarth
E-Jahr:2021
Jahr:September 2021
Umfang:8 S.
Fussnoten:Gesehen am 15.10.2021
Titel Quelle:Enthalten in: Journal of cataract and refractive surgery
Ort Quelle:Fairfax, Va. : Soc., 1986
Jahr Quelle:2021
Band/Heft Quelle:47(2021), 9, Seite 1210-1217
ISSN Quelle:1873-4502
Abstract:Purpose: - To determine how the type of opacification would have compromised the function of intraocular lenses (IOLs) prior to explantation using metrology. - Setting: - David J Apple Laboratory, Heidelberg, Germany. - Design: - Laboratory investigation. - Methods: - Of 67 explanted IOLs, 28 with homogeneous calcification, 21 with localized calcification, and 18 subluxated IOLs without calcification that served as controls were identified. The modulation transfer function (MTF) cutoff (0.43 at 100 lp/mm) was used to define decreased optical quality, following the manufacturers' guidelines for IOL testing. Light scattering was evaluated in vitro using a clinical device. - Results: - Only 1 control IOL demonstrated a decreased MTF compared with 4 and 15 in the homogeneous and localized groups, respectively. The MTF-derived metrics did not differ between the homogeneous and control IOLs (P = .99), but both showed better performance than those with localized opacification (P < .001). The median straylight parameter in the homogeneous pattern was 181.8 deg2/sr (108.5 to 244.1 deg2/sr), but in the localized group, it was less [69.8 (17.7 to 250.8) deg2/sr] (P = .02). Both opacification patterns yielded a significant straylight increase compared with the controls (P < .001). - Conclusions: - The study demonstrated that optical quality differed between the 2 types of opacification. The centrally localized pattern showed a significant MTF reduction, indicating a larger potential to affect patient visual acuity. Although localized calcification demonstrated lower straylight than that found in the homogeneous form, both conditions may cause severe glare phenomena.
DOI:doi:10.1097/j.jcrs.0000000000000553
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext: https://doi.org/10.1097/j.jcrs.0000000000000553
 Volltext: https://journals.lww.com/jcrs/Abstract/2021/09000/Optical_function_of_intraocular_lenses_in.17.aspx
 DOI: https://doi.org/10.1097/j.jcrs.0000000000000553
Datenträger:Online-Ressource
Sprache:eng
K10plus-PPN:1774173980
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68790404   QR-Code
zum Seitenanfang