| Online-Ressource |
Verfasst von: | Mathy, René Michael [VerfasserIn]  |
| Fritz, Franziska [VerfasserIn]  |
| Mayer, Philipp [VerfasserIn]  |
| Klauß, Miriam [VerfasserIn]  |
| Grenacher, Lars [VerfasserIn]  |
| Stiller, Wolfram [VerfasserIn]  |
| Kauczor, Hans-Ulrich [VerfasserIn]  |
| Skornitzke, Stephan [VerfasserIn]  |
Titel: | Iodine concentration and tissue attenuation in dual-energy contrast-enhanced CT as a potential quantitative parameter in early detection of local pancreatic carcinoma recurrence after surgical resection |
Verf.angabe: | René Michael Mathy, Franziska Fritz, Philipp Mayer, Miriam Klauss, Lars Grenacher, Wolfram Stiller, Hans-Ulrich Kauczor, Stephan Skornitzke |
E-Jahr: | 2021 |
Jahr: | October 2021 |
Umfang: | 7 S. |
Fussnoten: | Gesehen am 20.10.2021 |
Titel Quelle: | Enthalten in: European journal of radiology |
Ort Quelle: | Amsterdam [u.a.] : Elsevier Science, 1990 |
Jahr Quelle: | 2021 |
Band/Heft Quelle: | 143(2021) vom: Okt., Artikel-ID 109944, Seite 1-7 |
ISSN Quelle: | 1872-7727 |
Abstract: | Purpose - Due to the difficult differentiation from non-specific postoperative soft tissue formation (PSF), early diagnosis of pancreatic carcinoma recurrence remains challenging. Thus, we investigated the diagnostic potential of dual-energy (DE) contrast-enhanced CT. - Method - After potentially curative pancreatic carcinoma resection, 31 consecutive patients with PSF were examined via DE perfusion CT, acquiring 34 images (80 kVp/140 kVp) every 1.5 s, as the initial purpose of this study was evaluating CT-Perfusion. Corresponding time points of arterial, pancreatic, and early venous phase were calculated from bolus trigger times in prior conventional CT. Iodine and 120 kVp-equivalent images were calculated. Regions of interest were placed in each soft tissue formation. Diagnosis of local recurrence was confirmed by regular follow-up or histopathology. - Results - Final diagnosis was local recurrence in 17 patients and non-specific PSF in 14 patients. Iodine concentrations in early venous phase were significantly higher in recurrent carcinoma than in non-specific PSF (1.47 mg/ml vs. 0.96 mg/ml, p = 0.007). In earlier contrast phases iodine concentrations tended to be higher, but not significantly. CT numbers in recurrent carcinoma in 120 kVp-equivalent images in venous phase were significantly higher, too (74HU vs 47HU, p = 0.002). ROC-curve analysis for iodine concentrations in early venous phase suggests a cut-off value of ≥ 1.55 mg/ml for local recurrence (AUC = 0.78, specificity = 1.0, sensitivity = 0.53) and for CT numbers in 120kVp-equivalent images a cut-off value of ≥ 57HU (AUC = 0.82, specificity = 0.82, sensitivity = 0.71). - Conclusion - In difficult cases, measuring iodine concentrations or CT numbers in PSF in (early) venous phase DECT could be a valuable additional parameter for differentiating local recurrence from non-specific PSF. |
DOI: | doi:10.1016/j.ejrad.2021.109944 |
URL: | Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.
Volltext: https://doi.org/10.1016/j.ejrad.2021.109944 |
| Volltext: https://www.sciencedirect.com/science/article/pii/S0720048X21004253 |
| DOI: https://doi.org/10.1016/j.ejrad.2021.109944 |
Datenträger: | Online-Ressource |
Sprache: | eng |
Sach-SW: | Computed tomography |
| Dual-energy CT |
| Iodine concentration |
| Pancreatic carcinoma recurrence |
| Postoperative soft tissue formation |
K10plus-PPN: | 1774607034 |
Verknüpfungen: | → Zeitschrift |
Iodine concentration and tissue attenuation in dual-energy contrast-enhanced CT as a potential quantitative parameter in early detection of local pancreatic carcinoma recurrence after surgical resection / Mathy, René Michael [VerfasserIn]; October 2021 (Online-Ressource)