Standort: ---
Exemplare:
---
| Online-Ressource |
Verfasst von: | Habibi, Yasamin [VerfasserIn]  |
| Dawid, Marie-Theres [VerfasserIn]  |
| Waldecker, Moritz [VerfasserIn]  |
| Rammelsberg, Peter [VerfasserIn]  |
| Bömicke, Wolfgang [VerfasserIn]  |
Titel: | Three-year clinical performance of monolithic and partially veneered zirconia ceramic fixed partial dentures |
Verf.angabe: | Yasamin Habibi, Marie-Theres Dawid, Moritz Waldecker, Peter Rammelsberg, Wolfgang Bömicke |
Jahr: | 2020 |
Umfang: | 8 S. |
Fussnoten: | First published: 30 January 2020 ; Gesehen am 26.11.2021 ; This research was orally presented at the 68th Annual Scientific Meeting of the German Society of Prosthetic Dentistry and Biomaterials, Rostock, Germany |
Titel Quelle: | Enthalten in: Journal of esthetic and restorative dentistry |
Ort Quelle: | Oxford [u.a.] : Wiley-Blackwell, 2001 |
Jahr Quelle: | 2020 |
Band/Heft Quelle: | 32(2020), 4, Seite 395-402 |
ISSN Quelle: | 1708-8240 |
Abstract: | Objective To compare the 3-year survival and success rates of monolithic (M) and partially veneered (PV) zirconia-fixed partial dentures (FPDs). Materials and Methods Sixty-seven FPDs (n = 33 M-FPDs; n = 34 PV-FPDs) were placed in 51 patients (n = 23 males; mean age 61.5 years) and clinically followed up 1 week, 6 months, and then yearly after placement. One hundred per cent (100%) of M-FPDs and 70% of PV-FPDs were located in the posterior region. Ninety-two per cent (92%) of M-FPDs had three units, whereas 50% of PV-FPDs had more than three units. A facial veneer was present in 73% of the PV-FPDs units. Survival and success were calculated using the Kaplan-Meier method and compared using the log-rank test (α = .05). Results The mean observation period was 3.5 years for M-FPDs and 3.1 years for PV-FPDs. Most complications associated with FPDs were biological in nature. Ceramic defects occurred exclusively among PV-FPDs. Three-year survival was 96.7% for M-FPDs and 93.8% for PV-FPDs (P = .064). Three-year success was 93.8% for M-FPDs and 81.7% for PV-FPDs (P = .039). Conclusions The use of both M-FPDs and PV-FPDs yielded clinically successful results over a mean period of 3 years. Clinical Significance By using monolithic or facially veneered zirconia, ceramic FPDs could be fabricated which showed only a minimum of technical complications over the period of investigation without sacrificing adequate esthetics. |
DOI: | doi:10.1111/jerd.12568 |
URL: | kostenfrei: Volltext ; Verlag: https://doi.org/10.1111/jerd.12568 |
| kostenfrei: Volltext: https://onlinelibrary.wiley.com/doi/abs/10.1111/jerd.12568 |
| DOI: https://doi.org/10.1111/jerd.12568 |
Datenträger: | Online-Ressource |
Sprache: | eng |
Sach-SW: | fixed dental prosthesis |
| survival |
| chipping |
| esthetics |
| fixed partial denture |
| zirconia ceramic |
| zirconium dioxide |
K10plus-PPN: | 1779629265 |
Verknüpfungen: | → Zeitschrift |
|
|
| |
Lokale URL UB: | Zum Volltext |
Three-year clinical performance of monolithic and partially veneered zirconia ceramic fixed partial dentures / Habibi, Yasamin [VerfasserIn]; 2020 (Online-Ressource)
68805609