Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Rabsilber, Tanja Marina [VerfasserIn]   i
 Rudalevicius, Paulius [VerfasserIn]   i
 Jasinskas, Vytautas [VerfasserIn]   i
 Holzer, Mike P. [VerfasserIn]   i
 Auffarth, Gerd U. [VerfasserIn]   i
Titel:Influence of +3.00 D and +4.00 D near addition on functional outcomes of a refractive multifocal intraocular lens model
Verf.angabe:Tanja M. Rabsilber, MD; Paulius Rudalevicius, MD, FEBO; Vytautas Jasinskas, MD, FEBO; Mike P. Holzer, MD, FEBO; Gerd U. Auffarth, MD, FEBO
Jahr:2013
Umfang:8 S.
Fussnoten:Gesehen am 10.12.2021
Titel Quelle:Enthalten in: Journal of cataract and refractive surgery
Ort Quelle:Fairfax, Va. : Soc., 1986
Jahr Quelle:2013
Band/Heft Quelle:39(2013), 3, Seite 350-357
ISSN Quelle:1873-4502
Abstract:Purpose - To clinically evaluate different near additions (adds) (+3.00 diopters [D] and +4.00 D) of the M-flex 630F refractive multifocal intraocular lens (IOL). - Setting - Departments of Ophthalmology, University of Heidelberg, Germany, and Lithuanian University of Health Sciences, Kaunas, Lithuania. - Design - Clinical prospective nonrandomized unmasked study. - Methods - Preoperatively, cataract patients were assigned to receive bilateral +3.00 D IOLs, +4.00 D IOLs, or +3.00 D (dominant eye) and +4.00 D (nondominant eye) IOLs. Follow-up examinations were performed up to 6 months postoperatively and included refraction, visual acuity (near at 40 cm and distance), the defocus curve, contrast sensitivity, and a subjective questionnaire. - Results - Fifty-two patients were enrolled. No significant differences were found in the visual acuity results (P>.05). Four to 6 months postoperatively, the following median uncorrected and corrected distance visual acuity, uncorrected and distance-corrected near visual acuity, and corrected near visual acuity (logMAR) were found in all patients: −0.08, −0.12, 0.20, 0.10, and 0.10. Ninety-eight percent of patients reported being satisfied. The highest near peak versus the biggest intermediate decline in the median monocular defocus curves comparing +3.00 D and +4.00 D multifocal IOLs (logMAR) were 0.16 at 40 cm versus 0.22 at 33 cm (P=.24) and 0.38 at 66 cm versus 0.54 at 50 cm (P<.01). - Conclusion - Compared with the +4.00 D add, the +3.00 D near add gave better intermediate results in the defocus curve without compromising distance or near visual acuity. - Financial Disclosure - Drs. Rabsilber, Holzer, and Auffarth have received travel reimbursement and lecture fees from Rayner Intraocular Lenses Ltd. No other author has a financial or proprietary interest in any material or method mentioned.
DOI:doi:10.1016/j.jcrs.2012.09.026
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext: https://doi.org/10.1016/j.jcrs.2012.09.026
 Volltext: https://journals.lww.com/jcrs/Abstract/2013/03000/Influence_of__3_00_D_and__4_00_D_near_addition_on.8.aspx
 DOI: https://doi.org/10.1016/j.jcrs.2012.09.026
Datenträger:Online-Ressource
Sprache:eng
K10plus-PPN:1780930224
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68811278   QR-Code
zum Seitenanfang